2011 purple code Mound Design <br /> www SepticResource corn fivers 15 2) <br /> Property Owner: Judson Dayton Date: 12/4/2017 <br /> Site Address: Topside Addition PID: 0911723210001 <br /> Comments: Proposed Lot 1 Site B <br /> instructions: I =enter data =adjust if desired = computer calculated. DO NOT CHANGE! <br /> i) 5 bedroom Type { I Residential System <br /> 2) 750 GPD design flow <br /> 3) Yes Garbage disposal or pumped to septic 50%larger tank with multiple comp/tanks <br /> 4) 2250 Gal Septic tank(code minimum) 2250 Gal Septic tank(design size/ LUG req'd) <br /> Tank options: none <br /> 5) 1.2 GPD/ft2 mound sand loading rate contour loading rate of 12 req's a min 62.5 ft. long rockbed <br /> 6) 10.0 ft rockbed width 63.0 ft rockbed length <br /> 7) 3.0 ft lateral spacing 3.0 ft perforation spacing (maximum of 3 for both) <br /> end feed manifold connection <br /> 8) 3 laterals 61.0 feet tong 21.0 perfs / lateral 63 perfs total <br /> (1/2 a pert means the first pert starts at the middle feed manifold) <br /> 9) 7/32 inch perfs at 1 feet residual head gives 0.56 gpm flow rate per perforation <br /> for this pert size&spacing, &pipe size on line 12, max perfs/lateral= 30 , line#8 must be less - > OK <br /> )o) 4.0 doses per day (4 minimum) <br /> II) 188 gallons per dose (treatment volume) <br /> 2.00 5x <br /> 12) 2.00 inch diameter laterals must be used to meet"4x pipe volume"requirement <br /> 2.00 3x <br /> 13) feet of 2.0 inch supply line leads to #####gallons of drainback volume <br /> (Tip:"top feed"manifold to control the drainback) <br /> )4) ######gallons TOTAL pump out volume (treatment+drainback) <br /> is) feet vertical lift from pump to mound laterals, leads to a: <br /> 16) 36 GPM @ #####:feet of head, Pump requirement (note: >50gpm may require an extra 3-6 of head) <br /> 17) 750 gal Dose tank (code minimum) 1300 gal Dose tank(design size / LUG req'd) at 25.49 gpi <br /> leads to a <br /> is) ###### inch swing on Demand float, or timed dosing of ##### min ON (confirm pump rate with drawdown <br /> (this delivers Average flow, =70%of Peak design flow) ##### hrs OFF test and adjust as necessary) <br /> 19) _ 12 inches from bottom of tank to"Pump OFF"float <br /> 20) ###### inches from bottom of tank to"Pump ON"float, or 12 inches to"Timer ON"float if time dosed <br /> 2)) ######inches from bottom of tank to"Hi Level"float, or ##### inches to"Hi Level"float if time dosed <br /> 22) ######gallons reserve capacity (after High Level Alarm is activated) <br />