<br /> ; -, ; ,,,; TABLE A-29-A—MINIMUM PLUMBING FIXTURES,2,3
<br /> ,` WATER CLOSETS5 LAVATORIES6 A
<br /> 1z, j (fixtures per person) (fixtures per person)
<br /> 1-� ) . BATHTUB OR SHOWER C
<br /> t --TYPE OF BUILDING OR OCCUPANCY4 MALE FEMALE MALE FEMALE (fixtures per person) Z
<br /> IV r
<br /> - For the occupancies listed below,use 30 square feet(2.29 m2)per occupant for the minimum number of plumbing fixtures. TO
<br /> ti' Group A 73
<br /> Conference rooms,dining rooms,drinking 1:1-25 1:1-25 one for each water closet up to four; 03
<br /> •ettablishments,exhibit rooms, 2:26.75 2:26-75 then one for each two additional water c
<br /> gymnasiums;Jounges,=stages and similar 3:76-125 3:76-125 closets F
<br /> uses including restaurants classified as 4:126-200 4:126-200 v t
<br /> roup B;Occupancies- -- 5:201-300- 5:201-300 . --- - Z
<br /> • :^=i'I ;,,. 6:301-400 6:301-400
<br /> r€..: 1<'rlf... i• - Over 400,add one fixture for each n
<br /> i additional 200.males or 150 females. o
<br /> 52 For the assembly occupancies listed below,use the number of fixed seating or,where no fixed seating is provided,use 15 square feet(1.39 m2)per occupant for the m
<br /> li{ minimum number of plumbing fixtures. ='• = '41,
<br /> '1. Assembly;placesT-,t:,, tt `''
<br /> Auditoriums,convention halls,dance 1:1-50 3:1-50 1:1-200 I:1-200 +'' ;
<br /> �toorst lodge rooms,stadiums and casinos 2:51-100 4:51-100 2:201-400 2:201-400 r
<br /> a 3:101-150 6:101-200 3:401-750 3:401-750
<br /> r ' '% 't` '1' 4:151-300` 8:201-400 Over 750,add one fixture for each
<br /> ? ...4
<br /> , cf ' Over 300 males,add one fixture for additional 500 persons. .=
<br /> f" ow=' ( each additional 200,and over 400 et.:
<br /> 1€tn ,n> ,:, S,, ,.. females add one for each 125.
<br /> tit,, For.the assembly occupancies listed below,use the.number of fixed seating or,where no fixed seating is provided,use 30 square feet(2.29 m2)per occupant for the
<br /> ', Minimum of plumbing fixtures.
<br /> ti Worship places .
<br /> ,j, Principal assembly area one per 150 one per 75 one per 2 water closets
<br /> Worship places `
<br /> iii Educational and activity unit one per 125 one per 75 one per 2 water closets
<br /> Eor,the occupancies listed below,use 200 square feet(18.58 m2)per occupant for the minimum number of plumbing fixtures. x;
<br /> Group B -a � xF
<br /> Offices or public buildings 1:1-15 1:1-15 one per 2 water closets - J ;
<br /> >:, 2:16-35 2:16-35 m £ ,
<br /> 3:36-55 3:36-55 0
<br /> Over 55,add one for each 50 persons. X
<br /> C) ,Ear xr
<br /> (Continued) DO.