Laserfiche WebLink
It is recommended that a more appropriate distribution of exit width be achieved to accommodate <br /> the large increase of occupants exiting at the ice surface level. The addition of additional exit <br /> doors at the east entrance is a desirable option. <br /> III. Occupant Load in Ice Sheet Area <br /> The ice rink dasher boards,provided by the owner under separate contract, are programmed to <br /> remain permanently in place. The dasher board contractor is to provide and verify the required <br /> exit width and code compliant hardware as per UBC and review their documents with the gov- <br /> erning code official at the City of Orono. <br /> IV.Plumbing Fixture Requirements <br /> Total Occupant Load: 2066 <br /> 1033 Men: <br /> Fixtures Required: 8 WC and 4 Lay. <br /> Fixtures Provided: 4 WC +4 Urinals + 6 Lay. <br /> 1033 Women: <br /> Fixtures Required: 13 WC and 4 Lay. <br /> Fixtures Provided: 9 WC +7 Lay. <br /> The additional requirement for 4 womens water closets which could be accomplished with <br /> temporary satellite toilet facilities during the exceptional cases when the arena is to accommo- <br /> date the total allowable occupant load. <br /> Mark,please let me know if you have any questions or comments. <br /> 1;7 <br /> Victor Pechaty AIA <br /> Ted Rozeboom Archit cts <br />