Laserfiche WebLink
3. Structural Configuration: <br /> a. Submittals: Verify mill test reports and other submitted documentation, for <br /> compliance with contract documents. (Structural I) <br /> b. Materials: Verify materials delivered to site comply with contract documents and <br /> approved shop drawings(Technical I): <br /> Bolts <br /> Electrodes <br /> Mechanical Fasteners <br /> Deck Gauge <br /> • <br /> 4. Conventional Testing and Inspection Requirements: <br /> a. High Strength Bolting: <br /> 1) Bolt Material Test: Test a minimum of two bolts of each ASTM class <br /> specified, for bolt hardness and tensile properties. (SNT-TC-1A) <br /> 2) Fabrication and Erection Tolerances: Verify in-place structure satisfies <br /> specified tolerances. (Contractor) <br /> 5. If special inspection of fabricators work is required, testing agent may test and inspect <br /> structural steel at plant before shipment. Owner and SER reserve right to reject <br /> material not complying with Contract Documents at any time before final acceptance. <br /> 6. Definitions: <br /> a. A.S.N.T. -The American Society for Non-destructive Testing. <br /> b. N.D.E. -Non-destructive Evaluation. <br /> c. A.W.S./C.A.W.I. -American Welding Society/Certified Associate Weld <br /> Inspector. <br /> d. A.W.S./C.W.I. -American Welding Society/Certified Weld Inspector. <br /> D. The parties involved shall complete and sign the Special Structural Testing and Inspection <br /> Schedule. The completed schedule is an element of the construction documents and after <br /> permit issuance, becomes part of the building department approved plans and <br /> specifications. The completed schedule shall include the following: <br /> 1. A specific listing of the items requiring inspection and testing. <br /> ADDENDUM#1 <br /> 1607.001 - ORONO ICE ARENA(CP-2) Page 01410 - 12 <br />