My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Addendums to drawings/specs
Orono
>
Property Files
>
Street Address
>
O
>
Old Crystal Bay Road North
>
1025 Old Crystal Bay Road North - No PID
>
Misc
>
Addendums to drawings/specs
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/15/2023 7:19:49 AM
Creation date
3/15/2018 1:44:12 PM
Metadata
Fields
ProcessedPID
True
Tags
No PIN
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
207
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
3. Testing of high strength bolting, fillet weld and partial penetration weld testing will <br /> be waived if fabrication shop satisfies AISC Quality Certification Program- <br /> Category I,or more stringent criteria,or is approved by building official and SER. <br /> a. SER and Building Official will reinstate shop welding test requirements if work <br /> is considered questionable through visual observation of an ITL. <br /> PART 3 EXECUTION <br /> 3.1 ERECTION <br /> A. Erect structural steel in accordance with reviewed shop drawings,AISC Specification and <br /> Code of Standard Practice. <br /> B. Provide temporary shoring and bracing as required during erection. <br /> C. Install high strength bolts in conformance with AISC Specification for Structural Joints <br /> using ASTM A325 or A490 Bolts. If Tension Control Bolts or Load Indicator Bolts are <br /> used bolts shall be installed following recommendations of manufacturer. Hardened steel, <br /> round,flat washer shall be used under each nut and bolts shall be tightened until wrench <br /> twists off spliced ends. <br /> D. Install headed shear connector studs in accordance with manufacturer's instructions and <br /> AWS Structural Welding Code. <br /> E. Do not field cut openings through structural steel members for passage of conduit,pipes, <br /> or ducts without obtaining written permission from Architect. Wherever permission is <br /> given,provide openings and additionally reinforce member as directed by Architect. <br /> F. Clean concrete and masonry bearing surfaces below steel base and bearing plates of any <br /> bond-reducing materials. Clean bottom surfaces of base and bearing plates. Set plates at <br /> correct elevations by using steel wedges,shims,adjustable nuts or other devices. Pack <br /> specified non-shrink grout solidly between bearing surfaces and plates to insure that no <br /> voids remain.Mix,install,protect and cure grout in accordance with manufacturer's <br /> instructions. <br /> G. After erection of shop painted items clean bolted connections and abraded areas of primer <br /> and touch-up connections and prime coat with same paint material as used for shop coat. <br /> Do not paint members or areas of steel where painting is not required. <br /> H. After erection of galvanized items any areas damaged by welding,flame cutting,or during <br /> handling,transport or erection shall be repaired whenever damage exceeds 3/16 inch in <br /> width. Surfaces to be reconditioned shall be clean,dry,and free of oil, grease and <br /> corrosion products. Power sand disc areas to bright metal extending into undamaged <br /> galvanized coating. Apply specified touch-up paint by spray or brush in multiple coats to <br /> achieve dry film thickness of 8 mils minimum. Where damaged area will remain exposed <br /> apply finish coat of aluminum paint to provide color blend with surrounding galvanizing. <br /> ADDENDUM#1 <br /> 1607.001 -ORONO ICE ARENA(CP-2) Page 05120-6 <br />
The URL can be used to link to this page
Your browser does not support the video tag.