My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2016-00602 - alarm system
Orono
>
Property Files
>
Street Address
>
O
>
Old Crystal Bay Road North
>
0800 Old Crystal Bay Road North - 28-118-23-43-0010
>
Permits/Inspections
>
2016-00602 - alarm system
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:25:48 PM
Creation date
3/14/2018 3:15:12 PM
Metadata
Fields
Template:
x Address Old
House Number
800
Street Name
Old Crystal Bay
Street Type
Road
Street Direction
North
Address
800 Old Crystal Bay Road North
Document Type
Permits/Inspections
PIN
2811823430010
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
39
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• High nuisance-alarm immunity. by the very high-speed microcomputer used by the NFS2- <br /> 3030. <br /> FSA-8000 INTELLIGENT FAAST DETECTOR <br /> • Connects directly to the SLC loop of compatible ONYX Drift Compensation and Smoothing. Drift compensation <br /> allows the detector to retain its original ability to detect actual <br /> series panels smoke, and resist false alarms, even as dirt accumulates. It <br /> • Provides five event thresholds that can be individually pro- reduces maintenance requirements by allowing the system to <br /> grammed with descriptive labels for control-by-event pro- automatically perform the periodic sensitivity measurements <br /> gramming;uses five detector addresses. required by NFPA 72. Smoothing filters are also provided by <br /> • Uses patented particle separator and field-replaceable filter software to remove transient noise signals, usually caused by <br /> to remove contaminants. electrical interference. <br /> • Advanced algorithms reject common nuisance conditions Maintenance Warnings. When the drift compensation FCO-851/NTE�LIQUADT""PLUS per- <br /> formed for a detector reaches a certain level,the performance <br /> of the detector may be compromised, and special warnings <br /> ADVANCED MULTI-CRITERIA FIRE/CO DETECTOR are given. There are three warning levels: (1) Low Chamber <br /> • Detects all four major elements of a fire. value; (2) Maintenance Alert, indicative of dust accumulation <br /> • Separate signal for life-safety CO detection. that is near but below the allowed limit; (3) Maintenance <br /> Optional addressable sounder base for Temp-3 (fire) or Urgent,indicative of dust accumulation above the allowed limit. <br /> • Temp-4(CO)tone. Sensitivity Adjust. Nine sensitivity levels are provided for <br /> • Automatic drift compensation of smoke sensor and CO cell. alarm detection. These levels can be set manually, or can <br /> High nuisance alarm immunity. change automatically between day and night. Nine levels of <br /> • pre-alarm sensitivity can also be selected, based on predeter- <br /> FMM-4-20 GAS DETECTION MODULE mined levels of alarm. Pre-alarm operation can be latching or <br /> Interface to industry standard linear scale 4 20 mA sensors. self-restoring,and can be used to activate special control func- <br /> • tions. <br /> • Five programmable thresholds. Self-Optimizing Pre-Alarm. Each detector may be set for <br /> • FM Approved, Class 6320 (Stationary Gas Sensors/ "Self-Optimizing"pre-alarm. In this special mode,the detector <br /> Detectors). "learns" its normal environment, measuring the peak analog <br /> RELEASING FEATURES readings over a long period of time, and setting the pre-alarm <br /> level just above these normal peaks. <br /> • Ten independent hazards. <br /> Sophisticated cross zone(three options). Cooperating Multi-Detector Sensing. A patented feature of <br /> • ONYX Intelligent Sensing is the ability of a smoke sensor to <br /> • Delay timer and Discharge timers(adjustable). consider readings from nearby sensors in making alarm or <br /> • Abort(four options). pre-alarm decisions.Without statistical sacrifice in the ability to <br /> resist false alarms, it allows a sensor to increase its sensitivity <br /> VOICE AND TELEPHONE FEATURES to actual smoke by a factor of almost two to one. <br /> • Up to eight channels of digital audio. <br /> • 35 watt,50 watt,75 watt,and 100/125 watt digital amplifiers Field Programming Options <br /> (DAA2/DAX series and DS series). Autoprogram is a timesaving feature.The FACP"learns"what <br /> • Solid state message generation. devices are physically connected and automatically loads <br /> • Hard-wired voice control module options. them in the program with default values for all parameters. <br /> • Firefighter telephone option. Requiring less than one minute to run,this routine allows the <br /> user to have almost immediate fire protection in a new installa- <br /> • 30-to 120-watt analog amplifiers(AA Series). tion,even if only a portion of the detectors are installed. <br /> • Backup tone generator and amplifier option. Keypad Program Edit. The NFS2-3030, like all NOTIFIER <br /> intelligent panels, has the exclusive feature of program cre- <br /> FlashScan® Exclusive ation and editing capability from the front panel keypad,while <br /> World-Leading Detector Protocol continuing to provide fire protection. The architecture of the <br /> At the heart of the NFS2-3030 is a set of detection devices and NFS2-3030 software is such that each point entry carries its <br /> device protocol—FlashScan(U.S.Patent 5,539,389).FlashS own program, including control-by-event links to other points. <br /> can is an all-digital protocol that gives superior precision and This allows the program to be entered with independent per <br /> high noise immunity. point segments,while the NFS2-3030 simultaneously monitors <br /> other(already installed)points for alarm conditions. <br /> As well as giving quick identification of an active input device, <br /> this protocol can also activate many output devices in a frac- VERIFIRE®TOOLS <br /> tion of the time required by competitive protocols. This high VeriFire®Tools is an offline programming and test utility that <br /> speed also allows the NFS2-3030 to have the largest device can greatly reduce installation programming time, and <br /> per loop capacity in the industry— 318 points — yet every increase confidence in the site-specific software. It is Win- <br /> input and output device is sampled in less than two seconds. dows®based and provides technologically advanced capabili- <br /> The microprocessor-based FlashScan®detectors have bicolor ties to aid the installer. The installer may create the entire <br /> LEDs that can be coded to provide diagnostic information, program for the NFS2-3030 in the comfort of the office,test it, <br /> such as device address during Walk Test. store a backup file,then bring it to the site and download from <br /> a laptop into the panel. <br /> ONYX Intelligent Sensing <br /> ONYX Intelligent Sensing is a set of software algorithms that <br /> provide the NFS2-3030 with industry-leading smoke detection <br /> capability. These complex algorithms require many calcula- <br /> tions on each reading of each detector,and are made possible <br /> DN-7070:K•12/20/2013—Page 3 of 8 <br />
The URL can be used to link to this page
Your browser does not support the video tag.