My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2016-00602 - alarm system
Orono
>
Property Files
>
Street Address
>
O
>
Old Crystal Bay Road North
>
0800 Old Crystal Bay Road North - 28-118-23-43-0010
>
Permits/Inspections
>
2016-00602 - alarm system
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:25:48 PM
Creation date
3/14/2018 3:15:12 PM
Metadata
Fields
Template:
x Address Old
House Number
800
Street Name
Old Crystal Bay
Street Type
Road
Street Direction
North
Address
800 Old Crystal Bay Road North
Document Type
Permits/Inspections
PIN
2811823430010
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
39
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
dn-6724:b1 <br /> FCM-1 (A) & FRM-1 (A) <br /> Series NOTIFIER <br /> Control and Relay Modules by Honeywell <br /> Intelligent/Addressable Devices <br /> General <br /> FCM-1(A)Control Module: The FCM-1(A)Addressable Con- <br /> trol Module provides Notifier intelligent fire alarm control pan- <br /> els a circuit for Notification Appliances (horns, strobes, <br /> speakers, etc.)Addressability allows the FCM-1(A)to be acti- lif <br /> vated, either manually or through panel programming, on a <br /> select(zone or area of coverage)basis. Aave <br /> FRM-1(A)Relay Module: The FRM-1(A) Addressable Relay <br /> Module provides the system with a dry-contact output for acti- <br /> vating a variety of auxiliary devices, such as fans, dampers, „ ' <br /> control equipment,etc.Addressability allows the dry contact to *4 <br /> be activated, either manually or through panel programming, ', <br /> on a select basis. frt,, <br /> tleFlashScan®(U.S. Patent 5,539,389) is a communication pro- • rAig <br /> tocol developed by NOTIFIER Engineering that greatly , <br /> enhances the speed of communication between analog intelli- <br /> gent devices. Intelligent devices communicate in a grouped <br /> fashion. If one of the devices within the group has new infor- <br /> mation,the panel CPU stops the group poll and concentrates <br /> on single points.The net effect is response speed greater than <br /> five times that of other designs. FCM-1(A) <br /> Features <br /> • Built-in type identification automatically identifies these • The FCM-1(A)is configured for a single Class B(Style Y)or <br /> devices to the control panel. Class A(Style Z)Notification Appliance Circuit. <br /> • Internal circuitry and relay powered directly by two-wire • The FRM-1(A) provides two Form-C dry contacts that <br /> SLC loop.The FCM-1(A)module requires power(for horns, switch together. <br /> strobes,etc.),or audio(for speakers). <br /> • Integral LED "blinks" green each time a communication is Operation <br /> received from the control panel and turns on in steady red Each FCM-1(A)or FRM-1(A)uses one of 159 possible module <br /> when activated. addresses on a SLC loop (99 on CLIP loops). It responds to <br /> • LED blink may be deselected globally(affects all devices). regular polls from the control panel and reports its type and <br /> • High noise immunity(EMF/RFI). status, including the open/normal/short status of its Notifica- <br /> tionThe FCM-1(A) be used to switch 24 volt NAC power, Appliance Circuit (NAC). The LED blinks with each poll <br /> • audioeCM(up 1 70.7) mayVrbe received. On command, it activates its internal relay. The <br /> FCM-1(A) supervises Class B (Style Y) or Class A (Style Z) <br /> • Wide viewing angle of LED. notification or control circuits. <br /> • SEMS screws with clamping plates for wiring ease. Upon code command from the panel, the FCM-1(A) will dis- <br /> • Direct-dial entry of address 01— 159 for FlashScan loops, connect the supervision and connect the external power sup- <br /> 01 —99 for CLIP mode loops. ply in the proper polarity across the load device. The <br /> • Speaker, and audible/visual applications may be wired for disconnection of the supervision provides a positive indication <br /> Class B or A(Style Y or Z). to the panel that the control relay actually turned ON. The <br /> external power supply is always relay isolated from the corn- <br /> Applications munication loop so that a trouble condition on the external <br /> power supply will never interfere with the rest of the system. <br /> The FCM-1(A)is used to switch 24 VDC audible/visual power, Rotary switches set a unique address for each module. The <br /> high-level audio(speakers), or control telephone devices.The address may be set before or after mounting. The built-in <br /> FRM-1(A) may be programmed to operate dry contacts for TYPE CODE(not settable)will identify the module to the con- <br /> applications such as door holders or Air Handling Unit shut- trol panel, so as to differentiate between a module and a sen- <br /> down,and to reset four-wire smoke detector power. sor address. <br /> NOTE: Refer to the SLC Manual(PN 51253)for details regarding <br /> releasing applications with the FCM-1(A). Refer to the FCM-I-REL Specifications for FCM-1(A) <br /> datasheet(DN-60390)for new FlashScan0 releasing applications. <br /> Normal operating voltage: 15 to 32 VDC. <br /> Construction Maximum current draw: 6.5 mA(LED on). <br /> • The face plate is made of off-white heat-resistant plastic. Average operating current: 350 pA direct poll,375 pA group <br /> • Controls include two rotary switches for direct-dial entry of poll with LED flashing, 485 pA Max. (LED flashing, NAC <br /> address(01-159). shorted.) <br /> dn-6724:b1•08/04/09—Page 1 of 2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.