DN-6935:D•H-202 <br /> FSP-851 (A) Series <br /> NOTIFIER <br /> Intelligent Plug-In Photoelectric <br /> 9 9 <br /> Smoke Detectors with FlashScan® by Honeywell <br /> Intelligent/Addressable Devices <br /> General <br /> Notifier FSP-851(A) Series intelligent plug-in smoke detectors <br /> with integral communication provide features that surpass con- <br /> ventional detectors. Detector sensitivity can be programmed in <br /> the control panel software.Sensitivity is continuously monitored <br /> and reported to the panel.Point ID capability allows each detec- <br /> tor's address to be set with rotary, decimal address switches, <br /> providing exact detector location for selective maintenance ; l <br /> when chamber contamination reaches an unacceptable level. <br /> The FSP-851(A)photoelectric detector's unique optical sensing <br /> chamber is engineered to sense smoke produced by a wide <br /> range of combustion sources. Dual electronic thermistors add <br /> 135°F (57°C) fixed-temperature thermal sensing on the FSP- <br /> 851T(A).The FSP-851 R(A)is a remote test capable detector for <br /> use with DNR(A)/DNRW duct detector housings. FSP-851(A) <br /> series detectors are compatible with Notifier Onyx and CLIP FSP-851(A) in B210LP(A) Base <br /> series Fire Alarm Control Panels(FACPs). <br /> FlashScan®(U.S.Patent 5,539,389)is a communication proto- —B200SR(A):6.875"(17.46 cm)diameter. <br /> col developed by Notifier that greatly increases the speed of <br /> —B224RB(A):6.2"(15.748 cm)diameter. <br /> communication between analog intelligent devices. Intelligent <br /> devices communicate in a grouped fashion.If one of the devices —B224BI(A):6.2"(15.748 cm)diameter. <br /> in the group has new information, the panel's CPU stops the Shipping Weight:5.2oz.(147g). <br /> group poll and concentrates on single points. The net effect is Operating Temperature range: FSP-851(A), 0°C to 49°C <br /> response speed greater than five times that of earlier designs. (32°F to 120°F). FSP-851T(A), 0°C to 38°C (32°F to 100°F). <br /> Low temperature signal for FSP-851T(A) at 45°F +/- 10°F <br /> Features (7.22°C+/-5.54°C).FSP-851 R(A)installed in a DNR(A)/DNRW, <br /> -20°C to 70°C(-4°F to 158°F). <br /> • Sleek,low-profile design. <br /> • Addressable analog communication. UL/ULC Listed Velocity Range: 0-4000 ft/min. (1219.2 m/ <br /> • Stable communication technique with noise immunity. min.),suitable for installation in ducts. <br /> • Low standby current. Relative Humidity: 10%-93%noncondensing. <br /> • Two wire SLC connection. Thermal Ratings:Fixed-temperature setpoint 135°F(57°C). <br /> • Compatible with FlashScan®and CLIP protocol systems. DETECTOR SPACING AND APPLICATIONS <br /> • Rotary,decimal addressing(1-99 on CLIP systems, 1-159 on Notifier recommends spacing detectors in compliance with <br /> FlashScan systems). NFPA 72. In low airflow applications with smooth ceiling,space <br /> • Optional remote,single-gang LED accessory. detectors 30 feet (9.144m) for ceiling heights 10 feet(3.148m) <br /> • Dual LED design provides 360°viewing angle. and higher. For specific information regarding detector spacing, <br /> • Visible bi-color LEDs blink green every time the detector is placement, and special applications refer to NFPA 72. System <br /> addressed, and illuminate steady red on alarm (FlashScan Smoke Detector Application Guide, document A05-1003, is <br /> systems only). available at systemsensor.com <br /> • Remote test feature from the panel. ELECTRICAL SPECIFICATIONS <br /> • Walk test with address display(an address on 121 will blink Voltage Range:15-32 volts DC peak. <br /> the detector LED: 12-[pause]-1(FlashScan systems only). <br /> Standby Current(max.avg.): 300pA ® 24VDC(one commu- <br /> • Built-in functional test switch activated by external magnet. nication every five seconds with LED enabled). <br /> • Built-in tamper-resistant feature. LED Current(max.):6.5mA Com?24 VDC("ON"). <br /> • Sealed against back pressure. <br /> • Constructed of off-white fire-resistant plastic, designed to Installation <br /> commercial standards,and offers an attractive appearance. <br /> • 94-5V plastic flammability rating. FSP-851(A) plug-in detectors use a separate base to simplify <br /> • SEMS screws for wiring of the separate base. installation, service, and maintenance. A special tool allows <br /> maintenance personnel to plug in and remove detectors without <br /> • Optional relay,isolator,and sounder bases. using a ladder. <br /> Mount base(all base types)on an electrical backbox which is at <br /> Specifications least 1.5" (3.81 cm) deep. For a chart of compatible junction <br /> Sensitivity:0.5%to 2.35%per foot obscuration boxes,see DN-60054. <br /> Size:2.1"(5.3 cm)high;base determines diameter. NOTE: 1) Because of inherent supervision provided by the SLC <br /> —B210LP(A):6.1"(15.5 cm)diameter. loop, end-of-line resistors are not required. Wiring 'T-taps" or <br /> branches are permitted for Style 4 (Class "B") wiring. 2) When <br /> —B501(A):4.1"(10.4 cm)diameter. using relay or sounder bases, consult the ISO-X(A) installation <br /> —B200S(A):6.875"(17.46 cm)diameter. <br /> DN-6935:D•12/08/2011—Page 1 of 2 <br />