Laserfiche WebLink
DN-60408:D3 <br /> IPDACT-2/2UD NOTIFIER® <br /> FireWatch rm IP Series: <br /> IP Fire Alarm Communicator by Honeywell <br /> Miscellaneous <br /> General <br /> The new FireWatchTm IPDACT-2 and IPDACT-2UD are IP <br /> Communicators from NOTIFIER. These IP Communicators <br /> are UL 864 listed for signaling under Other Transmission Tech- <br /> nologies and comply with NFPA 72 requirements. <br /> Refer to the IPDACT Series Installation Document PN 53109 <br /> for more information. <br /> Both models connect to the primary and secondary communi- <br /> cation ports of the panel's DACT,converting the analog signals <br /> into digital signals at the panel for transmission to a compatible <br /> Teldat VisorALARM PLUS IP receiver at a central station.The <br /> panel operates normally during an alarm, supervisory or trou- o <br /> ble event and sends contact-ID formatted analog information ' l <br /> out of the telephone ports to the IP Communicator. The IP <br /> Communicator reformats the data into highly encrypted Ether- <br /> net UDP packets for transmission to a compatible receiver at <br /> the central station.This new listing only requires an IP connec- <br /> tion. No backup analog phone line is necessary. Customers the master username and password are correct, full duplex <br /> can still use a traditional backup phone line from the panel's communication is permitted to the panel. <br /> second phone port if desired. <br /> compatible Contact ID DACT-equipped panels, the IP NOTE:UL 864 Ninth Edition prohibits downloading to a panel with- <br /> WithCommunicators allow for faster and more economic digital out entering a local panel password. Uploading is permitted at any <br /> time without entering a password. <br /> alarm transmissions, improving response times and decreas- <br /> ing costs found with traditional analog systems. They offer Features <br /> supervised line functionality,where a central station can detect <br /> any off-line alarm panels within seconds.On the central station • Listed to UL Standard 864, Ninth Edition when used with <br /> side, a compatible VisorALARM® Plus IP receiver from the Notifier UL 864 Ninth Edition-listed panels. <br /> Teldat Corporation emulates popular receiver formats and • Eliminates the cost of two dedicated phone lines. Only the <br /> allows seamless integration into existing conventional central customer's shared IP equipment is required. <br /> station architectures. • Increases connection supervision to the central station from <br /> The benefit of an IP Communicator is that it is always on, the once-a-day test signal to once every 30-90 seconds. <br /> increasing the security and supervision of the central station • Requires no change to the existing panel configuration.The <br /> connection from once every 24 hours for a supervisory test IP Communicator connect directly to the primary and sec- <br /> signal to once every 30-90 seconds. ondary analog panel telephone ports. <br /> The IPDACT-2UD allows a programmer to upload and down- • Fast alarm transmission(less than 10 second transmission <br /> load data between the users PC and a supported fire alarm time). <br /> panel. The panel and PC can be anywhere on the world wide • Works over any type of customer-provided Ethernet 10/100 <br /> web or within a corporate intranet. Base network connection (LAN or WAN), DSL modem or <br /> The user's computer runs a program called UDPORT.exe to cable modem. <br /> capture the modem signals from PS-Tools panel programming • Data transmits over standard contact-ID protocol but is <br /> software.In UDPORT.exe the user enters the main IP address secured with the industry's highest level of encryption(AES <br /> of the VisorALARM receiver, the UDP port to use, username, 512 bit). <br /> and password. Instead of using the PC's modem,this process <br /> communicates between the IPDACT-2UD's modem at the • Supports both dynamic(DHCP)or Public and Private Static <br /> panel and the panel's own modem.While speed is still limited IP addressing. <br /> to the baud rate of the panel's modem, panel communications • Supports dual-destination IP receiver address for high <br /> are now 100%digital over IP from the remote program PC all redundancy configurations:all signals are sent to a second- <br /> the way to the remote panel installation. This eliminates any ary address should the primary become unavailable. <br /> dropouts in modem communications caused by noise or other • User programmable UDP ports for flexibility and compatibil- <br /> factors. If an alarm should occur during upload or download, ity with firewalls and other network security components. <br /> the panel is able to interrupt modem communications immedi- • Supports an optional third maintenance receiver installed at <br /> ately and transmit the alarm to the central station. the end user's facility that permits local alarm monitoring. <br /> Each IPDACT-2UD is registered in the VisorALARM Receiver Alarms are received simultaneously at both the central sta- <br /> with a unique serial number. A subscriber number must be tion and the customer's facility. A filter can be applied to <br /> entered into the subscriber number database field for each annunciate specific alarm types such as trouble-only <br /> IPDACT-2UD. This same number is entered into the sub- events. <br /> scriber telephone number field(panel to call) in PS-Tools as if • Supports upload/download using existing,familiar program- <br /> calling the panel on a telephone. If these numbers match, and ming tools. <br /> • Two supervised inputs and two outputs. <br /> DN-60408:D3•10/15/2014—Page 1 of 4 <br />