TFP161 <br /> Page 4 of 6 <br /> K SPRINKLER TEMPERATURE IQUIBD SPRINKLER FINISH 1101 <br /> TYPE RATING COLOR NATURAL CHROME POLYESTER*** LEAD WAX WAX-OVER-LEAD <br /> BRASS PLATED COATED COATED COATED <br /> 135°F(57°C) Orange <br /> 155°F(68°C) Red <br /> HORIZONTAL 175°F(79°C) Yellow 1,2,3,4,9 1,2,3,9 1,2,3,9 <br /> SIDEWALL 1,2,3,9 <br /> (TY3351) 200°F(93°C) Green <br /> Figure 1 <br /> 5.6 286°F(141°C) Blue 1**,2**,3**,9** <br /> 1/2" <br /> NPT 360°F(182°C) Mauve 1,2,4,9 1,2,9 N/A <br /> RECESSED 135°F(57°C) Orange <br /> HORIZONTAL 155°F(68°C) Red <br /> SIDEWALL 1,2,3,9 N/A <br /> (TY3351)* 175°F(79°C) Yellow <br /> Figure 3 200°F(93°C) Green <br /> 135°F(57°C) Orange <br /> VERTICAL 155°F(68°C) Red <br /> SIDEWALL 5,6,7,9 <br /> 5.6 (TY3451) 175°F(79°C) Yellow 4,5,6,7,8,9 <br /> 1/2" PENDENT 5,6,7,9 <br /> NPT or 200°F(93°C) Green <br /> UPRIGHT 286°F(141°C) Blue 5**,6**,7**,9** <br /> Figure 2 <br /> 360°F(182°C) Mauve 4,5,6,8,9 N/A <br /> Notes: <br /> 1. UL Listed for use in Light and Ordinary Hazard Occupancies at a 4 to 12 inch(100 to 300 mm)top of deflector-to-ceiling distance <br /> 2. C-UL Listed for use in Light and Ordinary Hazard Occupancies at a 4 to 12 inch(100 to 300 mm)top of deflector-to-ceiling distance <br /> 3. FM Approved for use in Light Hazard Occupancies at a 4 to 12 inch(100 to 300 mm)top of deflector-to-ceiling distance <br /> 4. LPCB Approved(Ref.No.094a&007k)at a 4 to 6 inch(100 to 150 mm)deflector-to-ceiling distance <br /> 5. UL Listed for use in Light and Ordinary Hazard Occupancies <br /> 6. C-UL Listed for use in Light and Ordinary Hazard Occupancies <br /> 7. FM Approved for use in Light Hazard Occupancies <br /> 8. LPCB Approved(Ref.No.094a&007k) <br /> 9. Approved by the City of New York under MEA 354-01-E <br /> 10.Where Polyester Coated,Lead Coated,Wax Coated,and Wax-over-Lead Coated Sprinklers are noted to be UL and C-UL Listed,the sprinklers are UL and C-UL Listed as corro- <br /> sion-resistant sprinklers.Where Lead Coated,Wax Coated,and Wax-over-Lead Coated Sprinklers are noted to be FM Approved,the sprinklers are FM Approved as corrosion- <br /> resistant sprinklers. <br /> Installed with Style 10(1/2-NPT)or Style 40(3/4°NPT)3/4"Total Adjustment Recessed Escutcheon,as applicable <br /> `• 150°F(66°C)maximum ceiling temperature <br /> `•• Frame and deflector only <br /> N/A-Not Applicable <br /> TABLE A <br /> SERIES TY-B HORIZONTAL AND VERTICAL SPRINKLERS <br /> LABORATORY LISTINGS AND APPROVALS <br />