Laserfiche WebLink
IE <br /> P.,,....4301 York Ave <br /> St.Paul,Minnesota 55130 <br /> -- <br /> ‘4 ;71.11.2.71 K 1 N (651)558-3300 • (800)229-6263 <br /> AUTOMATIC SPRINKLER CO. Fax: (651)558 3310 <br /> AGREEMENT AND REPORT OF INSPECTION fip '91 <br /> SHEEP 1 of 2-Use separate sheet for each building inspected #INSPECTION t q 9 5 I <br /> MINNESOTA LICENSE NO.C , <br /> 41 <br /> REPORT TO i,D 4& ci E o _ BUILOCATION a <br /> STREET ; ♦,r " $LDG OR INSPECTOR I <br /> CITY&STATE kb / d ij DATE if©4/ /3 4 <br /> Customer hires Viking Automatic Sprinkler Company to conduct an inspection of the fire suppression system at the above location or building,and <br /> prepare a written report of that inspection for.an agreed upon fee.As part of this agreement,customer agrees to terms and conditions on rear of form <br /> and will complete the Owner's Section of this document. Viking Automatic Sprinkler Company will not be held liable for incorrect or unkown <br /> answers provided in the Owner's Section. <br /> Owner's Section(To be answered by Owner,Occupant or Customer) <br /> A. Explain any occupancy hazard changes since the previous inspection 4J4 4) <br /> B. Describe fire protection modifications made since last inspection: Q#..) ,.. <br /> C. Describe any fires since last inspection: N 0 eti 2.. t f <br /> D.When was the system piping last checked for stoppage,corrosion or foreign ma rial? /1..J g$ <br /> E. When was the thy-piping system last checked for proper pitch? , g} A It <br /> F. Are dry valves adequately protected from freezing? I,.)I <br /> G.Does the system tain low point drains? o Yes Of. If yes,please state how many and the general location of each: <br /> Signature Title Date <br /> Inspector's Section(All reference current inspection) N/A=NOT APPLICABLE <br /> 1 General <br /> a. Is the building occupied?.glees o No <br /> b. Are all systems in service? iiptes a No <br /> c. Does there appear to be a minimum of 184n.(457 mm)clearance between the top of the storage and the sprinkler deflectors? PKYes o No <br /> d. Does the valve hose on the sprinkler system(s)appear to be satisfactory? o Yes a No tll/A <br /> S 2 Control Valves(See Item 15) V <br /> 0,-. a. Do sprinkler system control valves appear to be in the appropriate open or closed position? IX/es o No <br /> b. Are control valves in the open position locked,sealed or equipped with a tamper switch? p'es o No <br /> 3 Water Supplies(See Item 16) ....................... <br /> a. Was a water flow test of main drain made at the sprinkler riser(s)? (likes o No <br /> 4 Tanks,Pumps,Fire Department Connections <br /> a. Are fire pumps,gravity tanks,reservoirs and pressure tanks,in good condition and properly maintained? o Yes o No Vlll/A <br /> b. Are fire department connections in satisfactory condition,couplings free,caps in place,and check valves tight? ,es a No o N/A <br /> Are they accessible and visible?Oes a No o N/A <br /> 5' Wet Systems <br /> a. Are cold weather valves(OS.&Y.)in the appropriate open or closed position? pies a No o N/A <br /> b. Have antifreeze system solutions been tested? o Yes o No ViAl/A <br /> c. Were the antifreeze test results satisfactory? o-Yes a No: 0,41/A <br /> _ <br /> if. In areas protected by wet system(s),does the building appear to be properly heated in all areas,including blind attics and perimeter areas <br /> where accessible? Q 1'es •❑No o N/A Doall exterior openings appear to be protected against freezing?totes. a No o N/A <br /> 6 Dry System(See Items 11 to 13) <br /> a. Are day valves(s)in service? o Yes o No PN/A <br /> b. Are the air pressures and priming water levels in accordance with the manufacture's instructions? o Yes o No N/A <br /> c. Has the operation of the air ornitrogen supplies been tested? u Yes a No T/A Are they in service? o Yes a No l/A <br /> d. Were all know low points drained during this inspection? a Yes o No l/A <br /> e. Did quick-opening devices operate satisfactorily? o Yes o No ( N/A y <br /> f. Did the dry valve(s)trip properly during the trip pressure test? a Yes a No fi;01.l/A <br /> 'g. Did the heating equipment in the dry-pipe valve room(s)operate at time of inspection? o Yes '❑No p¢A <br /> 7 Special Systems(See Item 14) .: <br /> a. Did the deluge or pre action valves operate properly during testing? o Yes ❑NoT/A <br /> b. Did the heat-responsive devices operate,properly during testing? o Yes o No opt. <br /> c. Did supervisory devices operate during testing? o Yes ❑No fltl/A <br /> 8 Alarms <br /> a. Did water motor(s)and gong(s)test satisfactorily? o Yes o No` "f+I/A <br /> b. Did electric alarm(s)test satisfactory? latiles ❑No o N/A <br /> - c. Did supervisory alarm service test satisfactory?O..Yes o No o N/A o' <br /> 9 Sprinklers a <br /> a. Do visible sprinklers appear to be free from corrosion,loading Or obstruction to spray discharge? les a No •"• x <br /> b: Are sprinklers less than 50 years,old? (Older sprinklers require sample testing). 1� a No .. - <br /> c. Are quick response and residential sprinklers less than 20'years old? (Older sprinklers require sample testing) pies o No a*A. <br /> d. Is stock of spare sprinklers available? Yes o No ..' 1 <br /> e. Does the exterior condition of sprinkler system appear to be satisfactory? t fes`o No g`I <br /> f. Do visible sprinklers appear to be of proper temperature rating for their locations?*Yes o No _ . <br /> 1A Explain'any"Nb'answers and comments:; ; <br /> u <br /> Signature: •r .till Date: IC) /5. � -I <br /> (R.,9/02/09) . ,. <br />