My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Sprinkler inspections
Orono
>
Property Files
>
Street Address
>
O
>
Old Crystal Bay Road North
>
0795 Old Crystal Bay Road North - 28-118-23-34-0003
>
Permits/Inspections
>
Sprinkler inspections
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:24:43 PM
Creation date
3/14/2018 11:18:32 AM
Metadata
Fields
Template:
x Address Old
House Number
795
Street Name
Old Crystal Bay
Street Type
Road
Street Direction
North
Address
795 Old Crystal Bay Road North
Document Type
Permits/Inspections
PIN
2811823340003
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
8
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
1301 L'Orient Street <br /> do St.Paul,Minnesota 55117 <br /> C‘irN (651)558-3300 • (800)2219-6263 <br /> AUTOMATIC SPRINKLER CO. Fax: (651)558-3310 <br /> Setting Tice Standard... <br /> AGREEMENT AND REPORT OF INSPECTION <br /> SHEET 1 of 2-'Use separate sheet for each building inspected = #INSPECTION d /3 J S <br /> MINNESOTA LICENSE NO.C005 <br /> REPORT TO OR won fy L L BUILDINGQOR LOCATION SA en <br /> STREET 47j q s Q Ld C1 rlAC AA 'Ga INSPECTOR "A 7- <br /> CITY <br /> CITY&STATE 0 /040 . r14 d _ DATE f fj <br /> Owner hires Viking Automatic Sprinkler Company to conduct an inspection of the fire suppression system at the above location or building,and <br /> prepare a written report of that inspection for an agreed upon fee. As part of this agreement,owner agrees to terms and conditions on rear of form and <br /> will complete the Owner's Section of this document. <br /> Owner's Section(To be answered by Owner or Occupant) <br /> A. Explain any occupancy hazard changes since the previous inspection: AJA,Aig <br /> B. Describe fire protection modifications made since last inspection: /JO id <br /> C. Describe arty fires since last inspection: /O OA)l <br /> D. When was the systenipiping last checked for stoppage,corrosion or foreign material? , <br /> E. When was the dry-piping system last checked for proper pitch? /0 f{. <br /> F. Are dry valves equately protected from freezing? iiJ 14- <br /> Signature Title_ Date <br /> Inspector's Section( responses reference current inspection) N/A=NOT APPLICABLE <br /> 1 General <br /> a. Is the building occupied? Yes o No <br /> b. Are all systems in service.f'i Yes a No <br /> c. Does there appear to be a minimum of 18 in.(457 mm)clearance between the top of the storage and the sprinkler deflectors? Yes o No <br /> d. Does the valve hose on the sprinkler system(s)appear to be satisfactory? a Yes a No p.N/A <br /> 2-Control Val'vesYSee 1 05) ; , ; <br /> a. Do sprinkler system control valves appear to be in the appropriate open or closed position?$Yes a No <br /> b. Are control valves in the open position locked,sealed or equipped with a tamper switch?it.Yes o No <br /> 3 Water Supplies(See Item 16) <br /> a. Was a water flow test of main drain made at the sprinkler riser(s)?0-Yes o No <br /> 4 Tanks,Pumps,Fire Department Connections <br /> a. Are fire pumps,gravity tanks,reservoirs and pressure tanks in good condition and properly maintained? o Yes a No 10 N/A <br /> b. Are fire department connections in satisfactory condition,couplings free,caps in place,and check valves tight?pf.Yes a No o N/A <br /> Are they accessible and visible?0-Yes o No o N/A <br /> 5 Wet Systems <br /> a. Are cold weather valves-(O.S.&Y.)in the appropriate open or closed position? a Yes a No N/A <br /> b. Have antifreeze system solutions been tested? a Yes o No FIN/A <br /> c. Were the antifreeze test results satisfactory? o Yes o No vot N/A <br /> d. In areas protected by wet system(s),does the building appearto be properly heated in-all areas,including blind attics and perimeter areas <br /> where accessible?O.Yes o No o N/A Do all exterior openings appear to be protected against freezing?pt.Yes o No o N/A <br /> 6 Dry System(See Items 11 to 13) <br /> a. Are dry valves(s)in service? a Yes o No bp N/A <br /> b. Are the air pressures and priming water levels in accordance with the manufacture's instructions? o Yes a No ;fa N/A <br /> c. Has the operation of the air or nitrogen supplies been tested? o Yes o No,N/A Are they in service? o Yes a No OW/ <br /> d. Were all know low points drained during this inspection? o Yes o No AN/A <br /> e. Did quick-opening devices operate satisfactorily? a Yes o No OLN/A <br /> f. Did the dry valve(s)trip properly during the trip pressure test? a Yes a No .N/A <br /> g. Did the heating equipment in the dry-pipe valve room(s)operate at time of inspection? o.Yes a No ofN/A <br /> 7 Special Systems(See Item 14) <br /> a. Did the deluge or pre-action valves operate properly during testing? a Yes o No 06.N/A <br /> b. Did the heat-responsive devices operate properly during testing? o Yes a No 49.N/A <br /> c. Did supervisory devices operate during testing? o Yes o No /A <br /> 8 Alarms <br /> a. Did water motor(s)and gong(s)test satisfactorily? a Yes o No N/A <br /> b. Did electric alarm(s)test satisfactory?of Yes a No a N/A <br /> c. Did supervisory alarm service test satisfactory?f Yes a No a N/A <br /> 9 Sprinklers <br /> a. Do visible sprinklers appear to be free from corrosion,loading or obstruction to spray discharge? OfYes o No <br /> b. Are sprinklers less than 50 years old? (Older sprinklers require sample testing)pYes o No <br /> c. Are quick response and residential sprinklers less than 20 years old? (Older sprinklers require sample testg)(0Yes• a No o N/A <br /> d. Is stock of spare sprinklers available? kYes a No <br /> e. Does the exterior condition of sprinIdesystem appear to be satisfactory?A.Yes a No <br /> f. Do visible sprinklers appear to be of proper temperature rating for their locationslt Yes o No <br /> 10 Explain any"No"answers and comments: <br /> Signature: 1 Date: /0 -f fo- ir <br /> (Rev.2/8/0% - _ <br />
The URL can be used to link to this page
Your browser does not support the video tag.