My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Sprinkler inspections
Orono
>
Property Files
>
Street Address
>
O
>
Old Crystal Bay Road North
>
0795 Old Crystal Bay Road North - 28-118-23-34-0003
>
Permits/Inspections
>
Sprinkler inspections
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:24:43 PM
Creation date
3/14/2018 11:18:32 AM
Metadata
Fields
Template:
x Address Old
House Number
795
Street Name
Old Crystal Bay
Street Type
Road
Street Direction
North
Address
795 Old Crystal Bay Road North
Document Type
Permits/Inspections
PIN
2811823340003
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
8
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
`>;,„„,,.'.:: , ,;,::,,,,.%.,..:: x' „ :v. ti� v^. .;;..y ` ...,.1/4. �;.. ..•c- ..+..a..;,i.;,,,Y,�7."r•:4o« N. w" 'r 47*".. Yrt' '+' i,j..,:. _ :y jA„'4401420#44 <br /> 1301 L'ORIENT STREET <br /> Iv, k I hi G ST.PAUL,MINNESOTA 55117 <br /> (651)558-3300•(800)-229-6263 <br /> AUTOMATIC SPRINKLER CO. FAX:(651)558-3310 <br /> SHEET 1 OF 2 Use separate sheet for each oudding inspection REPORT OF INSPECTION <br /> MINNESOTA LICENSE NO.C0000 WISCONSIN LICENSE NO.265989 <br /> REPORT TO L r..t.) 27' t wit' BUILDING OR LOCATION <br /> STREET 9 t "—, _ SrR.� INSPECTOR glire <br /> N� - DATE /C) / <br /> CITY.& STATE / / <br /> Owner's Section(To be answered by Owner or Occupant) <br /> • <br />' A. Explain any occupancy hazard changes since the previous inspection: N Q <br /> B. Describe fire protection modifications made since last inspectio ''"• ,..a I <br /> r•;' ;.: b.:. . -. - IC <br /> C. Describe any fires since last inspection. <br /> D. When was t system piping last ch ked for age,corrosion or foreign material? <br /> E. When wa a ry-pipi g system last Necked for proper pitch? <br /> F. Are dry e ade I protected f m freezing? <br /> Signat a Title Date <br /> Inspector's Section(All responses reference current inspection) NA =NOT APPLICABLE <br /> 1. General <br /> a. Is the building occupied?4-Yes No <br /> b. Are all systems in service?6-Yes. No <br /> c. Is there a minimum of 18 in. (457 mm)clearance between the top of the forage and the sprinkler deflectors?L-01.--Y-es ❑No <br /> d. Does aI le hheat tape appear to be satisfactory?❑Yes No A AA <br /> e. Dces the Nan se"2�fn the sprinkler systems)appear to be satisfactory? Yes No. <br /> 2. Control Valves(See Item 15.) <br /> a.Are all sprinkler system control valves and all other valves in the appropriate open or closed position?des ❑No <br /> b.Are all control valves in the open position locked, sealed or equipped with a tamper switch?des ❑No <br /> 3. Water Supplies(See Item 16.) <br /> a. Was a water flow test of main drain made at the sprinkler riser(s)?E Yes ❑No <br /> 4. Tanks,Pumps,Fire Department Connections <br /> a. Are fire pumps, gravity tanks,reservoirs and pressure tanks in good condition and properly maintained?❑Yes ❑No [NA <br /> _ b. Are fjre_departmgnt congections in,satisfactory condition, ottplings free,caps in place,and check valves tight?iX.Yes ❑No ❑NA <br /> Are they accessible and:visible?Mali---❑No w NA 4 ' „i <br /> 5. Wet Systems <br /> a. Are cold weather valves(O.S. & Y.)in the appropriate open or closed position? 'lies 0 No 0 NA <br /> b. Have antifreeze system solutions been tested?U Yes ❑No t'NA <br /> c.Were the antifreeze test results satisfactory?❑Yes U No L'-NA <br /> d. In areas protected by wet system(s), does the building appear to be properly heated in all areas, including blind attics and perimeter areas <br /> where accessible? Yes ❑No NA Do all exterior openings appear to be protected against freezing?[PI`Yes No NA <br /> 6. Dry System(See Items 11 to 13.) "" <br /> a. Are dry valve(s) in service?❑Yes 0 No 16-NA <br /> b. Are thelntlr pressures and priming water levels in accordance with the manufac er's instructions?❑Yes ❑No LTJ NA <br /> c. Has the operation of the air or nitrogen supplies been tested?❑Yes ❑No ,_J NA Are they in service?❑Yes ❑No [ZONA <br /> d.Were low points drained during this inspection?❑Yes 0 No 14-NA <br /> e. Did quick-opening devices operate satisfactorily?❑Yes 0 N Z bIA <br /> f. Did the dry valve(s)trip properly during the trip pressure test?❑Yes ❑No it'NA <br /> g. Did the heating equipment in the dry-pipe value room(s)operate at time of inspection ?❑Yes ❑No <br /> 7. Special Systems(See Item 14.) <br /> a. Did the deluge or pre-action valves operate properly during testing?❑Yes ❑No "-NA <br /> b. Did the heat-responsive devices operate properly during testing?E Yes 7 NoI1a'A <br /> c. Did supervisory devices operate during testing?E Yes 0 No 011tA <br /> 8. Alarms <: <br /> a. Did water motor(s)and gong(s)test sati§factotily?0 Yes 0 No WIC'd. <br /> b. Did electric alarm(s)test satisfactory?LR"Y'es 0 No 0 NA <br /> c. Did supervisory alarm service test satisfactory?V-Yes ❑No ❑NA <br /> 9. Sprinklers <br /> a.Ale all sprinklers free from corrosion,loading or obstruction to spray discharge?14-Yes 1 No <br /> b.Are sprinklers less de `5D"years old?(bider sprinklers require sample-testing)[ e¢ E No <br /> c. Are quick response and residential sprinklers less than 20 years old?(Older sprinklers require sample testing).19-Yes iE No <br /> d. Is stock of spare sprinklers available? ..Yes ❑No <br /> e. Does the exterior condition of sprinkler system appear to be satisfactory ?,6 res 0 No <br /> f. Are sprinklers of proper temperature rati f: . -ir locations?4•Y'es No <br /> 10.Explain any"No"ans . o corn 'e <br /> Signature: - • ate <br />
The URL can be used to link to this page
Your browser does not support the video tag.