PLAN REVIEW NOTES <br /> Church/Day Care <br /> A 2.1 Occupancy - Sanctuary <br /> - 3,207 s.f. ± divided by 7 = 458 occupants <br /> - 2 exits required - 4 proposed <br /> - distance to exits okay <br /> - 9' of exit width required - 18' proposed <br /> E-3 Occupancy - Day Care/Classroom <br /> - 684 s.f.± divided by 20 = 34 occupants <br /> - 1 exit required - 3 proposed <br /> - 3' exit width required - 9' proposed <br /> B-2 Occupancy - Offices <br /> - 734 s.f.± divided by 100 = 7 occupants <br /> - exiting okay <br /> Type of Construction <br /> Type V - one hour required <br /> Type proposed - not shown <br /> Location on Property <br /> 2 hour walls required less than 10' <br /> 1 hour walls required less than 40' <br /> Survey shows 48'+ to property lines <br /> Allowable Floor Area <br /> 10,500 allowed - 6,146 ± proposed <br /> Sanitation <br /> Required number of water closets + lavatories okay <br /> 1 water fountain required <br /> All equipment must be handicap accessible <br /> Comments <br /> - Sprinkler system must be extended throughout new addition <br /> - An approved fire alarm system tied into the sprinkler system must be provided <br /> - Exits from activity/sanctuary must be provided with panic hardware <br /> - Exit corridors from activity/sanctuary must be of 1 hour construction, doors must <br /> have 20 min. rating <br />