Laserfiche WebLink
,. <br /> etitt,9. i, `7! ..._r.Z. .,' * * .. 4,.... ,T.-...r-"a►!Rw-'•,,,.�+...-,;.._..yp r:1' 4.„/'"3 wre.G'%:o yTdirl s'► 4:nW-." .wd <br /> " "` 1301 L'ORIENT STREET <br /> 44 <br /> ST.PAUL,MINNESOTA 551171 <br />/l', <br /> 1 1 NG (651)558-3300.(800 -229-6263 <br /> AUTOMTIC SPRINKLER CO. FAX:(651)558-3310) <br /> SHEET 1 OF 2-Use separate sheet for each ou,ldung inspection <br /> REPORT OF INSPECTION <br /> MINNESOTA LICENSE NO.C00005 WISCONSIN LICENSE NO.265989 <br /> t. <br /> REPORT TO (---10.- O N U , i<=- BUILDING OR LOCATION J f <br />` STREET t r 0 fi`�i(Ij l t.r S/fyr-�1 :` t /./'; INSPECTOR ' <br /> 7)1 <br /> CITY &_STATE 6�CC�j(,/(7 /" r i/ I, ,. DATE <br /> Owner's Section(To be answered by Owner or Occupant) ` . <br /> A. Explain any occupancy hazard changes since the previous inspection: i.#' <br /> v <br /> , it) 4,,„--r . <br /> ..,�.4 B. Describe fire protection modifications made since last inspection. �'- <br /> J'e. 4,'.'4: - _ 1..\\*) <br /> ppn TrYkt <br /> C. Describe any fires since last inspection. Q _ <br /> D. When was t i- ste 't pipin. . t checked .r stoppage, corrosion or foreign material? <br /> E. When w:• e ,ryf.ing ste a ch l ed for proper pitch? <br /> F. Are dr valve •uatel pr . fro; freezing? <br /> Signatb 't i i` .4. --- Title/1 '� ''2' / Date <br /> F <br /> Inspector's Sect'.n(All responses reference current inspection) NA =NOT APPLICABLE <br /> 1. General �_• <br /> a. Is the balding occupied? Yes _No <br /> b. Are all systems in service?likes ❑No <br /> c. Is there a 'mum of 18 in.(457 mm)clearance between the top of the storage and the sprinkler deflectors?.l fes ❑No <br /> d. Does ail-elec aT aat tape appear to be satisfactory?❑Yes U No [ NA <br /> e. Does the hand hose on the sprinkler system(s)appear to be satisfactory?❑Yes —No. A <br /> r 2. Control Valves(See Item 15.) <br /> �: a. Are all sprinkler system control valves and all other valves in the appropriate open or closed position?tomes ❑No <br /> 4i. b. Are all control valves in the open position locked, sealed or equipped with a tamper switch?`Y°Yes ❑No <br /> 3. Water Supplies (See Item 16.) <br />--`"'r"' a. Was a water flow test of main drain made at the sprinkler riser(s)?des O.No <br /> 4. Tanks, Pumps,Fire Department Connections <br /> a. Are fire pumps,gravity tanks, reservoirs and pressure tanks in good condition and properly maintained?❑Yes ❑No t NA <br /> tt ,s b. Are',fire department connections i satisfactory condition,couplings free,gaps in place, andtcl1eck vflves tight?des ❑No U NA <br /> Are they accessible and visible?I"4'L{s i U.No _. NA f.= t <br /> 5. Wet Systems <br /> a. Are cold weather valves(O.S. & Y.) in the appropriate open or closed position? Yes ❑No ❑NA 1 <br /> .) b. Have antifreeze system solutions been tested?❑Yes ❑No i NA ' <br /> c. Were the antifreeze test results satisfactory?❑Yes ❑No -PIA • <br /> d. In areas protected by wet system(s),does the building appear to be properly heated in all areas, including blind attics and perimeter areas ' <br /> where accessible?PhYes ❑No ❑NA Do all exterior openings appear to be protected against freezing?fig-Yes ❑No ❑NA <br />' , 6. Dry System(See Items 11 to 13.) <br /> k` a. Are dryvalve(s)inS <br /> ,service?❑Yes ❑No NA <br />''- b. Are thOdir des and priming water levels in accordance with the manufacturer's instructions?❑Yes ❑No fI NA <br /> c. Has the operation of the air or nitrogen supplies been tested?❑Yes ❑No e?'tA Are they in service?❑Yes ❑No SNA <br /> d. Were low points drained during this inspection?❑Yes ❑No *DIA .: <br /> e. Did quick-opening devices operate satisfactorily?a Yes D.No ANA <br /> f. Did the dry valve(s)trip properly during the trip pressure test?❑Yes C No "NA <br /> g- Did the heating equipment in the dry-pipe value room(s)operate at time of inspection ?❑Yes ❑No PIN*rl <br />,* 7. Special Systems(See Item 14.) - I� `t t "r ,,,t <br /> t a. Did the deluge or pre-action valves operate properly during testing? Yes -. No (''NA ~r k t <br /> b. Did the heat-responsive devices operate properly during testing?❑Yes O No SFA <br /> c. Did supervisory devices operate during testing?U Yes ❑No 0+1A <br /> 8. Alarms <br /> - a. Did water motor(s)and gong(s)test satisfactorily?0 Yes ❑No li)b. Did electric alarms)test satisfactory?1�4 es ❑No ❑NA �c.Did supervisory alarm service test satisfactory? 9.-Yes ❑No ❑N ��I�«�`��L'�fOki <br /> 9. Sprinklers �/ <br /> a.Are all sprinklers free4frpm corrosion,fading pr obstruction to spray discharge ? es ❑No <br /> b. Are sprinklers less than 50 years old?(Older sprinklers require sample testing)testing)jilkices ❑'Nicr* - -= P,- -' <br /> c. Are quick response and residential sprinklers less than 20 years old?(Older sprinklers require sample testing)des LiNo - <br /> d. Is stock of spare sprinklers available?d'afes ❑No <br /> e. Does the exterior condition of sprinkler system appear to be satisfactory ?1s O No <br /> f.Are sprinklers of proper temperature rating for their locations?Vain ❑No <br /> 10.Explain any"No" wer and <br /> ft <br /> / f' <br /> Signature- �rr:fi =, 4i Date: _____Ze24Z.,/ -, <br /> 4 <br />