Geotechnical exploration/review-2008
Orono
>
Property Files
>
Street Address
>
O
>
Old Crystal Bay Road North
>
0550 Old Crystal Bay Road North - 33-118-23-13-0021
>
Misc
>
Geotechnical exploration/review-2008
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:47:50 PM
Creation date
3/9/2018 3:00:32 PM
Metadata
Fields
Template:
x Address Old
House Number
550
Street Name
Old Crystal Bay
Street Type
Road
Street Direction
North
Address
550 Old Crystal Bay Road North
Document Type
Misc
PIN
3311823130021
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
92
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
AMERICAN ENGINEERING TESTING, INC. AET Project No. 22-00012 <br /> We recommend that you plan the construction schedule to accommodate a minimum 30 day <br /> waiting period between the completion of site grading in the building pad, and the start of <br /> footing construction. If the construction schedule cannot accommodate this waiting period, then <br /> we strongly recommend that you authorize us to complete a supplemental field and laboratory <br /> testing program to further assess the potential settlement, and evaluate potential alternative site <br /> preparation methods. <br /> If there is space on the site to open a borrow pit, some of the on-site clay, silty sand, and sand <br /> might be reusable as fill in the building pads. Much of the on-site cohesive soils have elevated <br /> water contents, up to 41% at our borings; we estimate that the optimum water content is about <br /> 16% to 18%, based on the Standard Proctor test (ASTM: D 698), and soils with water contents <br /> above about 18% to 20% would require drying before use as compacted fill. Cohesive soils used <br /> as backfill must be dried to within 2% of the optimum water content before placement or treated <br /> with Class C fly ash or hydrated lime to achieve the desired compaction with reasonable effort <br /> and without drying. However, lime or fly ash treatment requires that the soil temperature be no <br /> lower than about 45°F at the time of treatment. It is beyond our scope of services to calculate the <br /> amount of suitable fill that might be available on the site. <br /> For imported fill in the building pads, we recommend using a granular soil with less than 12% <br /> passing the No. 200 sieve, such as Mn/DOT 3149.2B2 having no gravel larger than 3 inches. <br /> Alternatively,a lean clay(USCS Classification of CL or CL-ML), clayey sand(SC), or silty sand <br /> (SM) could be used. If the contractor proposes a different type of fill, a sample should be <br /> submitted to our laboratory for testing and review by a Geotechnical Engineer. <br /> The use of sand fill may be advantageous since the initial lift can be placed in a thicker lift than <br /> clay, while still achieving compaction. This would reduce the potential for disturbing the <br /> excavation base. Furthermore, there are several risks associated with using the on-site clay or <br /> imported silty/clayey soils as fill. Wet weather can increase the water content of the clay and <br /> require drying before it is used as compacted fill; this could significantly delay construction. If <br /> Page 12 of 28 <br />