2 I D285 Series Photoelectric Smoke Detector Heads (12/24 VDC) <br /> Chamber Check Feature Mounting <br /> To further reduce nuisance alarms,the D285 and D285TH The D285 smoke detector head and D285TH smoke and <br /> heads check their calibration.This Chamber Check feature heat detector head are parts of a compound device.The <br /> is automatic. If the head is out of calibration for a period detector base installs over a back box and contains all the <br /> exceeding 24 hours,the Trouble-Alarm LED flashes once wiring.The detector head attaches to the base by aligning <br /> per second, three times the normal rate. the head with the base and turning it clockwise. No tools <br /> Testing are required for installation other than the hex key used to <br /> Internal diagnostic test tighten the optional tamper screw. <br /> These heads have moisture-proof reed switches that react Wiring <br /> to an external magnet for testing. The magnet test The terminal block accepts up to 12 AWG (2.3 mm) wire. <br /> simulates a 4% to 6%smoke obscuration that places the <br /> detector in an alarm condition. This test results in specific <br /> LED and alarm circuit responses to indicate: Technical Specifications <br /> • Detector within calibration standards Environmental Considerations <br /> • Detector settings outside sensitivity standards <br /> • Detector not operational Radio Frequency No alarm or setup on critical frequencies in <br /> This test is especially useful in environmentally unstable Interference(RFI) the range from 26 MHz to 950 MHz at field <br /> or unclean areas. Immunity_ -- strengths less than 50V/m <br /> Sensitivity voltage test -Relative Humidity: Up to 93%,non_condensing_ <br /> These detector heads have a socket that accepts the Temperature(operating): +32°F to+100°F(0°C to+38°C) <br /> D1005 Test Cable.The D1005 connects to the detector Mechanical Properties <br /> head and allows a voltmeter to read the sensitivity of the <br /> device. Color: Bone white <br /> -- – — <br /> LEDs Dimensions(diameter x D): 4 in.x 1.25 in.(10.2 cm x3.2 cm) <br /> The D285 and D285TH have a built-in LED that flashes to Power Requirements <br /> indicate the device is powered.The LED latches on steady Current Two wire:depends on control panel that must limit the <br /> in an alarm condition. (alarm): alarm current to 100 mA maximum <br /> Four-wire:depends on detector base;refer to pertinent <br /> base specifications _ <br /> Certifications and Approvals Current Two-wire:0.08 mA at 12 VDC;0.09 mA at 24 VDC <br /> (standby): Four-wire(D293E):4 mA at 12 VDC or 24 VDC <br /> RegionCertification RMS Ripple 25%of DC input <br /> - i (maximum): <br /> USA UL UROX:Smoke-Automatic Fire Detectors <br /> Voltage(in Two-wire:8.5 VDC to 33 VDC <br /> (UL268 and A),UROX7:Smoke- put): Four-wire:10 VDC to 30 VDC <br /> Automatic Fire Detectors Certified for <br /> Canada(cULus) <br /> CSFM 7272-1615:0134 SMOKE DETECTOR- <br /> SYSTEM TYPE-PHOTOELECTRIC <br /> NYC-MEA 274-93-E,Vol.VII <br /> MSFM <br /> Hong Kong HKFSD <br /> Installation/Configuration Notes <br /> Note Smoke detectors are intended for detection <br /> circuits that protect people. Heat detectors <br /> are appropriate for circuits that protect <br /> property. <br />