FIRE ALARM ACCESSORY <br /> 5104B Fire Control <br /> Communicator <br /> SILENT KNIGHT <br /> MODEL 5104B <br /> 120VAC 60 Hz Silent Knight <br /> 6 Channel Model 5230 <br /> Class A Input O Communicator (optional) <br /> (supervised) <br /> Remote Annunciator <br /> (3 max per system) <br /> — <br /> 0 0 <br /> Class B Inputs Wheelock <br /> (supervised) MB-G10-12-R <br /> Heat detectors,manual 8Tel. Line#1 ` (optional) <br /> pull stations and To RJ31X <br /> contact type - Model 6712 <br /> smoke detectors 12VDC 7 AH . <br /> Tel. Line#2 <br /> MODEL 5104B BLOCK DIAGRAM <br /> Stand-alone Automatic Fire Detection Application <br /> (For Communication Only) <br /> ARCHITECT/ENGINEER and send the alarm signal on one or The digital communicator shall provide <br /> SPECIFICATIONS both lines without the addition of any a secondary power supply utilizing <br /> The contractor shall provide an more equipment. It shall test each rechargeable batteries.The secondary <br /> approved digital communicator to telephone line(number)at alternating supply shall be capable of supplying <br /> transmit the fire alarm and supervisory 24-hour intervals in accordance with power, under maximum normal load, <br /> and trouble signals to a central station. NFPA 72. It shall sound a local trouble for 24 hours for central station or <br /> The digital communicator shall be UL signal if the telephone service is proprietary applications or 60 hours for <br /> or FM listed for fire reporting to a interrupted for longer than 60 seconds remote supervising station system <br /> central station and shall conform to the and it shall transmit a signal indicating application in accordance with NFPA <br /> requirements of NFPA 72. the loss of phone line service to the 72. <br /> central station over the remaining The communicator shall be able to <br /> The digital communicator shall provide phone line.A signal shall also be transmit all signals in the Standard SIA <br /> power and necessary components for transmitted to indicate the restoral of format(Security Industry Association). <br /> six supervised detection circuits.One phone service.The The alarm signals transmitted to the <br /> shall be Class A(Style D)and five shall control/communicator shall be able to g <br /> be Class B (Style A).The detection report the loss of either phone line central station shall indicate which of <br /> circuits shall accommodate sprinkler without regard to which phone line the six zones is in alarm and which <br /> flow switches,gate valve supervisory failed first.If both lines fail,a local zones are in trouble. Restore!from <br /> switches,thermal detectors and signal shall sound. alarm or trouble shall be capable of <br /> contact-type smoke detectors communicating to Silent Knight, and <br /> intermixed as desired and permitted by The control/communicator shall have other industry standard receivers. <br /> NFPA 72. the ability to send a test signal to the <br /> central station every 24 hours.The test <br /> The control/communicator shall have signal shall be able to be transmitted at <br /> the capability to supervise two a specific time of day or night by <br /> telephone lines,seize the phone line setting a program within the panel. <br /> SILENT This document is not intended to be used for installation purposes.We try to MADE IN AMERICA <br /> `j KNIGHT keep our product information up-to-date and accurate.We cannot cover all <br /> specific applications or anticipate all requirements.All specifications are PN 350349,Rev Cl <br /> by Honeywell subject to change without notice.For more Information,contact Silent Knight ©2010 Honeywell International Inc. <br /> 12 Clintonville Road,Northford,CT 06472-1610.Phone:(800)328-0103, <br /> Fax:(203)484-7118. www.silentknight.com <br />