My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2015-00379 - sprinkler system
Orono
>
Property Files
>
Street Address
>
O
>
Old Crystal Bay Road North
>
0450 Old Crystal Bay Road North - 33-118-23-13-0020
>
Permits/Inspections
>
2015-00379 - sprinkler system
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:47:42 PM
Creation date
3/9/2018 11:47:59 AM
Metadata
Fields
Template:
x Address Old
House Number
450
Street Name
Old Crystal Bay
Street Type
Road
Street Direction
North
Address
450 Old Crystal Bay Road North
Document Type
Permits/Inspections
PIN
3311823130020
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
99
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
2 ( s -003-19 <br /> Li5D C) Id Calsslea(; <br /> CLIC(' Fire & Building bfK, 2 N <br /> Products <br /> Technical Services: Tel: (800)381-9312/Fax: (800)791-5500 <br /> Model 513 (13) Riser Manifold <br /> 1-1/2 thru 6 Inch (DN4O thru DN15O) <br /> For NFPA 13 Sprinkler Systems <br /> General Technical <br /> Description Data <br /> The Figure 513 (13) Riser Manifolds Approvals 0 <br /> described in this technical data sheet The Figure 513 (13) Riser Manifolds <br /> provide the necessary waterflow with a cover tamper switch for the wa- <br /> alarm, pressure gauge, alarm test ori- terflow alarm switch are UL Listed, <br /> fice, drain, and sight glass equipment ULC Listed, and FM Approved. <br /> in a single assembly for use in NFPA The Figure 513 (13) Riser Manifolds • <br /> 13 sprinkler systems as follows: without a cover tamper switch for the <br /> NFPA 13* waterflow alarm switch are UL Listed <br /> • 1 1/2 Inch (DN40) and FM Approved. <br /> Male Thread x Female Thread Maximum Working Pressure r <br /> • 1-1/2 thru 6 Inch(DN40 thru DN150) <br /> 175 psi (12,1 bar) <br /> Groove x Groove Test Orifice <br /> 5.6K(80K) <br /> 'Although the Riser Manifold described in Assembly <br /> this data sheet is intended for NFPA 13 nections and/or listed mechanical <br /> sprinkler systems,it may be used for NFPA The manifold body of the Figure 513 is grooved connections, as applicable <br /> 13D or 13R residential sprinkler systems, ductile iron, whereas the manifold <br /> where a test orifice of 5.6K(80K)is accept- body of the Figure 13 is cast iron. The Step 2. Connect the drain line, and <br /> able. two assemblies are completely inter- then close the drain valve. <br /> changeable in function, application, Step 3. Refer to Figure 3 for wiring <br /> The variety of sizes and grooved end and end-to-end laying length. guidance. All wiring must be per- <br /> connections allow cost effective and Finish formed in accordance with the Author- <br /> easy transition to check valves,control Red painted. ity Having Jurisdiction and/or the Na- <br /> valves, and system piping. The Riser tional Electrical Code. <br /> Manifolds may be installed in either the to Figure 4 for optional <br /> horizontal (flow switch on top)or verti- Installation Step 4.relief valRefere. <br /> cal (flow going up) for both single <br /> sprinkler rises and floor control in high The Riser Manifolds may be installed Step 5. Place the system in service by <br /> rises. in either the horizontal (flow switch on filling the system with water.When fill- <br /> top) or vertical (flow going up). The ing the system, partially open the con- <br /> WARNING inlet of the Riser Manifold may be di- trol valve to slowly fill the system. Fill- <br /> The Riser Manifolds described herein rectly connected to a shut-off control ing the system slowly will help avoid <br /> must be installed and maintained in valve. damaging the waterflow alarm switch. <br /> compliance with this document, as After the system is fully pressurized, <br /> well as with the applicable standards NOTES completely open the control valve. <br /> of the National Fire Protection Asso- Where applicable pipe thread sealant <br /> ciation, in addition to the standards of is to be applied sparingly. Use of a Step 6. Secure all supply valves <br /> any other authorities having jurisdic- non-hardening pipe thread sealant is open. <br /> tion. Failure to do so may impair the recommended. <br /> performance of these devices. Never remove any piping component <br /> The owner is responsible for maintain- nor correct or modify any piping defi- <br /> ing their fire protection system and de- ciencies without first depressurizing <br /> vices in proper operating condition. and draining the system. <br /> The installing contractor or sprinkler Step 1. Install the manifold body with <br /> manufacturer should be contacted the flow arrow pointing in the down- <br /> with any questions. stream position using threaded con- <br /> Page 1 of 6 APRIL, 2006 TFP962 <br />
The URL can be used to link to this page
Your browser does not support the video tag.