Laserfiche WebLink
TFP1510 <br /> Page 2 of 4 <br /> Nominal Nominal Installation Dimensions <br /> Valve OD Inches(mm) Weight <br /> Sizes Inches Lbs. <br /> Inches (mm) A B C D E F G H (kg) <br /> (DN) <br /> 2-1/2 2.88 3.85 11.94 3.25 5.67 5.90 5.82 2.13 22 <br /> (65) (73,0) (98,0) (303,3) (83,0) (144,0) (149,9) (147,8) (54,1) 0 (10,0) <br /> 3 3.50 3.85 12.48 3.54 5.94 5.90 5.82 2.13 23 <br /> (80) (88,9) (98,0) (317,0) (90,0) (150,9) (149,9) (147,8) (54,1) 0 (10,4) <br /> 4 4.50 4.56 14.18 4.35 6.31 5.90 7.64 2.13 28 <br /> (100) (114,3) (116,0) (360,2) (110,0) (160,3) (149,9) (194,1) (54,1) 0 (12,7) <br /> 5 5.56 5.86 15.17 4.84 7.32 5.90 7.64 2.13 31 <br /> (125) (141,3) (149,0) (385,3) (123,0) (185,9) (149,9) (194,1) (54,1) 0 (14,1) <br /> 6 6.63 5.86 17.54 5.93 8.62 5.90 7.64 2.13 0.67 41 <br /> (150) (168,3) (149,0) (445,5) (151,0) (218,9) (149,9) (194,1) (54,1) (17,0) (18,6) <br /> • <br /> 8 8.63 5.26 19.42 6.87 9.80 9.80 7.91 2.13 5.86 53 <br /> (200) (219,1) (134,0) (493,3) (174,0) (248,9) (248,9) (200,9) (54,1) (148,8) (24,1) <br /> 10 10.75 6.29 24.03 9.17 11.61 18.00 9.49 3.03 7.41 88 <br /> (250) (273,1) (160,0) (610,4) (233,0) (294.9) (457,2) (241,0) (77,0) (188,2) (40,0) <br /> INDICATOR <br /> -- G F - HANDWHEEL FLAG 1/2" NPT <br /> CONDUIT <br /> III CONNECTION <br /> GEAR -- ��•► <br /> OPERATOR Lam- , , E �0�� <br /> �1_ <br /> BODY B <br /> D -., ~~ DISC <br /> HC r <br /> �� 17 c -}—_., <br /> I , <br /> —A - <br /> FIGURE 1 <br /> MODEL BFV-N GROOVED END BUTTERFLY VALVE <br /> NOMINAL DIMENSIONS <br /> Installation switch" is intended for connection to tion Association (e.g., NFPA25), in ad- <br /> the supervisory circuit of a fire alarm dition to the standards of any author- <br /> The Model BFV-N Grooved End But- control panel in accordance with NFPA ity having jurisdiction. The installing <br /> terfly Valves may be installed with flow 72. The "auxiliary switch" is intend- contractor or product manufacturer <br /> in either direction and can be posi- ed for the unsupervised connection should be contacted relative to any <br /> tioned either horizontally or vertically. to auxiliary equipment in accordance questions. Any impairment must be <br /> with NFPA 70, National Electric Code. immediately corrected. <br /> The grooved end pipe couplings used <br /> with the Model BFV-N must be listed NOTE: For outdoor applications with NOTE:Before closing a fire protection <br /> or approved for fire protection service internal supervisory switches, it is rec- system control valve for maintenance <br /> and installed in accordance with the ommended that wiring connections or inspection work on either the valve <br /> manufacturers instructions. be made at a temperature above 15°F or fire protection system which it con- <br /> (-9°C), in order to insure sufficient flex- trols, permission to shut down the af- <br /> The Model BFV-N Butterfly Valve may ibility of the wire lead insulation. fected fire protection systems must be <br /> be installed with any schedule of pres- obtained from the proper authorities <br /> sure class of pipe or tubing that is list- and all personnel who maybe affected <br /> ed or approved for fire protection. Care and by this decision must be notified. <br /> As applicable, refer to Figure 2 for the Maintenance It is recommended that automatic <br /> internal switch wiring diagram. sprinkler systems be inspected, test- <br /> Conduit and electrical connections The owner is responsible for the in- ed, and maintained by a qualified in- <br /> are to be made in accordance with spection,testing,and maintenance of spection service. <br /> the authority having jurisdiction and/ their fire protection system and devic- <br /> or the National Electrical Code. With es in accordance with the applicable <br /> reference to Figure 2, the "supervisory standards of the National Fire Protec- <br />