My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
septic info including 2002 design
Orono
>
Property Files
>
Street Address
>
O
>
Old Crystal Bay Road North
>
0405 Old Crystal Bay Road North - 33-118-23-24-0007
>
Septic
>
septic info including 2002 design
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:48:10 PM
Creation date
3/7/2018 1:01:58 PM
Metadata
Fields
Template:
x Address Old
House Number
405
Street Name
Old Crystal Bay
Street Type
Road
Street Direction
North
Address
405 Old Crystal Bay Road North
Document Type
Septic
PIN
3311823240007
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
28
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
0.1 o <br /> 4 C of ORONO <br /> '�+►� �1:�, ;��1� ti" Mmicipal Offices <br /> X G <br /> Street Address: Mailing Address: <br /> ` E88o +2150 Kelley Parkway P.O. Box 66 <br /> Orono, MN 55356 Crystal Bay, MN 55323-0066 <br /> Owner: C ;ak S <br /> Address:_ old Cr ysral EV <br /> City Ordinance 199 requires that each existing on-site se ge treatment system in Orono be inspected every two years. <br /> The on-site sewage treatment system at the above address been inspected and appears to fall into the categories checked below. <br /> SYSTEM CONFORMITY (1-3): 1 <br /> 10 "CODE SYSTEM" An LOTS which meets all the location, edga and construction standards of the current Orono bfunicipal Cede. <br /> 2 "COIViPLIANT SYSTEM" An ISTs which does not m all the location,design and construction standards of the eurra>t Orono Municipal <br /> Code but does meet the three foot separation requirement,and •chis ant g err as imminent threat to public health or sar.:ty. <br /> 3 "NON-COMPLIANT SYSTEM" Aprohtluited ISIS; ISTS located within a designated 1170 year flood plair6 aay ISTS which may <br /> or may not meet all the location,design,or coastriuction of the cunni Orono Municipal Code and which is falling for any reason;and <br /> any ISIS with less than three feet of unsawrated soil or sand b the distribution device and the limiting wil characteristics. <br /> TANK CONDITION(5-10): 5� . <br /> Tank inspection indicates: <br /> `.J Puinpout not needed at this time. <br /> 6 Tank must be pumped out this year (city code requires tanks to b pumped out every 3 years. Tank was Last pumped 6'3 0—Q d 7 <br /> 7 Solids accumulation in tanks is at a critical a critical level. Tanks should be pumped out as soon as possible. <br /> 8 System is discharging to the surface. Tanks must be pumped out 'that 48 hours to eliminate surface discharge. <br /> 9 Inspection risers missing-tanks could not be inspected Irsspecdo risers(4"dia.pipe)must be installed in each tank at nest pumpout If tanks <br /> have not been pumped out within the last three years,they should be pumped out now. <br /> 10 Inspection pipe is located directly over tank baffle(does not give rate measurement of solids accumulation). If tanks have not beenpumped <br /> out within the last three years,they should be pumped out now. <br /> DRAiNFIELD CONDITION(11-14): 1 <br /> (`J'Drainfteld is dry,no surfacing evideaL <br /> 12 Some evidence of surfacing,not critical yet <br /> 13 Draintield is saturated and visibly discharging untreated effluent to a surface Contact the City Inspector immediately.Repairs must be <br /> completed«ithin 90 days <br /> 14 Drainfield extent and condition unknown. <br /> CONSENTS: 5 y 5+e r.. 10-0�5 0�C <br /> DM cu� <br /> Date oflnspection <br /> Septic System inspector <br /> Note: In the event that this inspection report is used to satisfy the requirements it a mortgage or other transfer of property,be advised tial this report does not guarantee <br /> or eertitjr that an e�sting system will eontiaue to function properly,but is merely an opinion of the adequacy of the system under wisest conditions based on the available <br /> information. <br />
The URL can be used to link to this page
Your browser does not support the video tag.