My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
septic info including septic design
Orono
>
Property Files
>
Street Address
>
O
>
Old Crystal Bay Road North
>
0365 Old Crystal Bay Road North- 33-118-23-31-0013
>
Septic
>
septic info including septic design
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:49:23 PM
Creation date
3/7/2018 12:42:33 PM
Metadata
Fields
Template:
x Address Old
House Number
365
Street Name
Old Crystal Bay
Street Type
Road
Street Direction
North
Address
365 Old Crystal Bay Road North
Document Type
Septic
PIN
3311823310013
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
21
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
On the North Sbore of <br /> Lake Minnetonka <br /> ON-SITE SEWAGE TREATMENT CITY <br /> INSPECTION REPORT OF POST OFFICE BOX 66 <br /> _ONO 1335 S. Brown Rd. <br /> Crystal Bay,MN 55323 <br /> Ilk 473-7357 <br /> OWNER ADDRESS <br /> PERMIT NO.'S. DATES --/ �7CONTRACTORS <br /> City Ordinance No.210 requires that each on-site sewage treatment system in Orono be inspected on a regular basis.The on-site sewage <br /> treatment system at the above address has been inspected and appears to fall into the category c ecked below. <br /> (This is 10 an existing system ❑ new construction) <br /> 01 Meets or exceeds current City standards in all respects relating to design,construction,and location.Appears to be operating <br /> properly. <br /> 2 Does not meet all current City standards for new construction (1978 Code but in most respects appears to be designed, <br /> located, and constructed generally in accordance with previous codes.System,appears to be functioning properly;no major <br /> upgrading of the system is required at this time. <br /> El3 Does not meet current City standards in many respects relating to design,construction,or location.Appears to be operating <br /> adequately at this time,but has a relatively high potential for future problem s. No major upgrading of system is required at <br /> this time. <br /> 04 System may or may not meet current City standards for design,construction or location, but is failing to properly treat and <br /> dispose of the current input,and is endangering a water supply,or is a source of pollution to surface or groundwaters,or is <br /> creating a safety hazard,or is otherwise creating a public nuisance.Please contact the City Inspector to discuss system repair/ <br /> replacement procedures. If drainf laid replacement is necessary,soil testing wil I usually be required,and a design and site plan <br /> must be submitted for review.Your contractor must obtain a permit before wok is started. <br /> SYSTEM CONDITION (® Checked items may require your action) <br /> Tank inspection indicates: 4-4Inspectionpipe is located directly over tank baffle.(Does not <br /> ❑ Pumpout not needed at this time. give accurate easurement of solids accumulation.) If tanks <br /> ❑ Solids accumulation in tanks indicates they should be pump- have not been umped out within the last three years,they <br /> ed out this year to help prevent future problems. should be pum d out now. <br /> ❑ Solids accumulation in tanks is at a critical level. Tanks Drairyleld inspection i dicates: <br /> should be pumped out as soon as possible. J1 Drainfield is dry,no surfacing evident. <br /> ❑ System is discharging to surface. Tanks must be pumped ❑ Some evidence f surfacing,not critical yet. <br /> within 48 hours to eliminate surface discharge. ❑ Drainfield is rated and visibly discharging untreated <br /> ❑ Inspection risers missing—tanks could not be inspected, effluent to the surface. This condition may require replace- <br /> Inspection risers (4"dia.pipe)must be installed in each tank ment or additions to drainfield. Contact the City Inspector <br /> at next pumpout. If tanks have not been pumped out within immediately.Ri pairs must be completed within 90 days. <br /> the last three years,they should be pumped out now. ❑ Drainfield exten and condition unknown. <br /> SITE CHARACTERISTICS: <br /> Limiting Site Factors Potential for System Failure Site Capabilities for <br /> ❑ Slope (depends on soil types,water Future Expansion <br /> ❑ Soil table,and system condition) ❑Adequate <br /> ❑ High water table Low %Fair <br /> ❑ Lot size Medium ❑Poor <br /> ❑ Lake,wetland,or stream ❑ High ❑ Inadequate <br /> ❑ Drainage ❑System is causing visible <br /> surface discharge. <br /> COMMENTS: � 1054 ✓!I l� <br /> M,✓ <br /> Date of Inspection Septic Syst m Inspector <br /> Note: In the event that this inspection report is used to satisfy the requirements for a mortga a or other transfer of property,be advised that <br /> this report does not guarantee or certify that an existing system will continue to function prol erly,but is merely an opinion of the adequacy <br /> of the system under current conditions based on the available information. <br /> This report must be kept on the premises with system location and Dumping records. <br /> WHITE COPY/Inspector's File GOLD C PY/Homeowner <br />
The URL can be used to link to this page
Your browser does not support the video tag.