Laserfiche WebLink
o o <br /> CITY of ORONO <br /> M cipal Offices <br /> G <br /> Street Address: Mailing Address: <br /> �` E+ggOg� 2150 Kelley Parkway P.O. Box 66 <br /> Orono, MN 55356 Crystal Bay, MN 55323-0066 <br /> Owner: Address: 65 Old Crystal Bay Rd. N. <br /> Permit Vs: 1736 Dates: 11/28/67 Contractors: Widmer Br s. <br /> (This is [,X] an existing system [ ] new construction) . <br /> SYSTEM COMPLIANCE (1-3) : 3 <br /> 1 Code System: Meets or exceeds current City standards in all respects relating to design, <br /> construction, and location. Appears to be operating proprly. <br /> 2 Compliant System: Does not meet all current City std rds for new construction, but in <br /> most respects appears to be designed, located, and consantr cted in accordance with previous <br /> codes and is functioning properly. <br /> Non-Compliant System: System may or may not meet cu rent City standards for design, <br /> construction, or location, but is failing to properly reat and dispose of the current <br /> input; and any system with less than three feet of verti al separation between the bottom <br /> of the drainfield and the saturated soil level. <br /> (The saturated soil level [X] has or [ ] has not been dentified at this time. If the <br /> saturated soil level has not been identified, this classifica ion is subject to revision.) <br /> TANK CONDITION (5-9) : 6 <br /> � Pumpout not needed at this time. <br /> Solids accumulation in tanks indicates they should be p ped out this year. <br /> System is discharging to the surface. Tanks must be pum ed out within 48 hours. <br /> 8 Inspection risers missing-tanks could not be inspected. If tanks have not been pumped out <br /> within three years, they should be pumped out and risers installed now. <br /> 9 Inspection pipe is located over tank baffle-can not meas re solids accumulation. If tanks <br /> have not been pumped out within three years, they should be pumped out now. <br /> (During the last septic tank Maintenance Pumpout the tanks [ ] were or [A] were not confirmed <br /> to be watertight by the licensed pumping contractor. If t e tanks were not confirmed to be <br /> watertight, this classification is subject to revision.) <br /> D INFIELD CONDITION (11-14) : 11 <br /> 1'1V Drainfield is dry, no surfacing evident. <br /> Some evidence of surfacing, not critical yet. Repair isl not required at this time. <br /> 13 Drainfield is saturated and visibly discharging untreated effluent to the surface. <br /> Contact the City Inspector immediately. Repair must beicompleted within 90 days. <br /> 14 Drainfield extent and condition unknown. <br /> POTENTIAL FOR SYSTEM FAILURE: (system age and condition, soils, etc.) : medium <br /> COMMENTS: In order to confirm that your septic system meet Minnesota standards, soil borings <br /> were performed to verify a 3 foot separation between the drainfield and the seasonal water <br /> table. The separation is 0 feet and the system is non-compl ant. Repair or replacement of the <br /> septic system is required by 12/31/2007. <br /> Date of Inspection S p is System Inspector <br /> Note: In the event that this inspection report is used o satisfy the requirements for a <br /> transfer of property, this report does not guarantee that existing system will continue to <br /> function properly, but indicates the operation of the system under current conditions. <br /> Telephone (612) 473-7357 9 FAR 47-0510 <br />