CITYof ORONO <br /> �,'� Municipal Offices <br /> �y Street "dress: Mailing Address: <br /> 2750 alley Parkway P.O. Box 66 <br /> y� Orono, MN 55356 Crystal Bay, MN 55323-0066 <br /> Owner: ! Address: 315 Old Crystal Bay Rd. N. <br /> Permit Vs: 2966 Dates: 12/6/71 Contrac ors: Widmer Bros. <br /> (This is [X an existing system [ I new con truction) . <br /> SYSTEM COMPLIANCE (1-3) : 3 <br /> 1 Code System: Meets or exceeds currentCi y standards in all respects relating to design, <br /> construction, and location. Appears to b operating properly. <br /> 2 Compliant System: Does not meet all cur ent City standards for new construction, but in <br /> most respects appears to be designed, loc ted, and constructed in accordance with previous <br /> codes and is functioning properly. <br /> 3O Non-Compliant System: System may or ma not meet current City standards for design, <br /> construction, or location, but is failin to properly treat and dispose of the current <br /> input; and any system with less than thre feet of vertical separation between the bottom <br /> of the drainfield and the saturated soil level. <br /> (The saturated soil level 04 4 has or [ ] s not been identified at this time. If the <br /> saturated soil level has not been identified, t s classification is subject to revision.) <br /> TANK CONDITION (5-9) : 9 <br /> 5 Pumpout not needed at this time. <br /> 6 Solids accumulation in tanks -indicates the should be pumped out this year. <br /> 7 System is discharging to the surface. Ta s must be pumped out within 48 hours. <br /> 8 Inspection risers missing-tanks could not a inspected. If tanks have not been pumped out <br /> within three years, they should be pumped ut and risers installed now. <br /> Inspection pipe is located over tank baffl -can not measure solids accumulation. If tanks <br /> have not been pumped out within three year , they should be pumped o���u//t now. <br /> (During the last septic tank Maintenance Pumpou the tanks ( ] were or L!�] were not confirmed <br /> to be watertight by the licensed pumping cont actor. If the tanks were not confirmed to be <br /> watertight, this classification is subject to r vision.) <br /> INFIELD CONDITION (11-14) : li <br /> (ly Drainfield is dry, no surfacing evident. <br /> 2 Some evidence of surfacing, not critical y t. Repair is not required at this time. <br /> 13 Drainfield is saturated and visibly di charging untreated effluent to the surface. <br /> Contact the City Inspector immediately. R pair must be completed within 90 days. <br /> 14 Drainfield extent and condition unknown. <br /> POTENTIAL FOR SYSTEM FAILURE: (system age and condition, soils, etc.) : medium <br /> COMMENTS: In order to confirm that your septic system meets Minnesota standards, soil borings <br /> were performed to verify a 3 foot separation between the drainfield and the seasonal water <br /> table. The separation is 0 feet and the system is non-compliant. Repair or replacement of the <br /> septic system is required by 12/31/2007. <br /> Date of Inspection S96iic System Inspector <br /> Note: In the event that this inspection rep rt is used to satisfy the requirements for a <br /> transfer of property, this report does not gua antee that an existing system will continue to <br /> function properly, but indicates the operation o the system under current conditions. <br /> Telephone (612) 47343$7 9 FAX 473-0510 <br />