Job Name: 20X24 9/12 Truss ID: Al Qty: 2 Drw : <br /> BRG X-IAC REACT SIZE REQ'D TC 2x6 SPF C1650F1.53 Designed per ANSI/TPI 1-2002 End verticals are designed for axial loads <br /> 1 0- 2-12 1787 5.50" 2.11" BC 2x8 SP 1950E-1.7E Kar (creep factor) - 1.00 only unless noted otherwise. <br /> 2 19- 9- 4 1787 5.50" 2.11" WEB 2x3 SPF STM-CAN Refer to Joint QC Detail Sheet for Extensions above or below the truss profile <br /> BRG REQDIREMENTS shown are based ONLY 2x6 SPF C1650F1.5E 9-2, 10-6 traxin tta Rotational Tolerance used (if any) have been designed for loads <br /> on the truss material at each bearing TIE BEAM 2x4 SPF STUD-CAN Attic room load= 43 psf, plus any added indicated only. Horizontal loads applied at <br /> ATTIC WE 2x4 SPF STUD-CAN loads indicated. Room LL Defl. is L/480. the end of the extensions have not been <br /> TO FORCE AXL END CSI GEL ELK 2x3 SPF STUD-CAN THIS DESIGN IS THE COMPOSITE RESULT OF considered unless shown. A drop-leg to an <br /> 1-2 -1616 0.01 0.50 0.51 Lumber shear allowables are per NDS. MULTIPLE LOAD CASES. otherwise unsupported wall may Create a <br /> 2-3 -1027 0.00 0.61 0.61 Loaded for 10 PSP non-concurrent BCLL. IRC/IBC truss plate values are based on binge affect that requires additional design <br /> 3-4 lee 0.00 0.61 0.61 One row of cross bridging (X-bracing) may be testing and approval as required by IBC 1703 consideration (by others). <br /> 4-5 188 0.00 0.61 0.61 required at centerline of room per NDS. and ANSI/TPI and are reported in available HORIZONTAL REACTION(S) <br /> 5-6 -1027 0.00 0.61 0.61 Attic collar tie requires lateral restraint documents as ER-1607 and ESR-1118. support 1 244 lb <br /> 6-7 -1616 0.01 0.50 0.51 shown, or rigid sheathing is required. Gable verticals are 2x 3 web material spaced support 2 -244 lb <br /> This truss is designed using the at 16.0 " o.c. unless noted otherwise. 20 psf bottom chord live load NOT required <br /> BC FORCE AXL END CSI ASCE7-05 Wind Specification Top chord supports 24.0 " of uniform load on this truss, per IBC/IAC requirements for <br /> 8-9 -245 0.00 0.35 0.35 Bldg Enclosed = Yes, Importance Factor = 1.00 at 35 psf live load and 7 psf dead load. attics with limited storage. <br /> 9-10 961 0.03 0.41 0.44 Truss Location =Not End Zone Additional design considerations may be ----------LOAD CASE 61 DESIGN LOADS --------------- <br /> 10-11 -245 0.00 0.35 0.35 Hurricane/Ocean Line - No Exp Category = B required if sheathing is attached. Dir L.Plf L.Loc R.Plf R.Loc LL/ <br /> Bldg Length = 99.99 ft, Bldg Width = 50.00 fdcace gable studs in accordance with TC Vert 104.00 - 1- 6- 0 104.00 0- 0- 0 0.6 <br /> WEB FORCE CSI NEB FORCE CSI Mean roof height = 26.00 ft, mph = 90 Truswal Systems standard gable bracing TC vert 84.00 0- 0- 0 84.00 4- 9- 4 0.8 <br /> 1-8 -1860 0.58 6-10 667 0.07 ASCE7 lI Standard Occupancy, Dead Load - 10.21citafcls and charts. TC Vert 94.00 4- 9- 4 94.00 7- 4-14 0.7 <br /> 1-9 1031 0.62 7-30 1031 0.62 Designed as Main Wind Force Resisting System This truss requires adequate sheathing, as TC Vert 84.00 7- 4-14 84.00 12- 7- 2 0.8 <br /> 2-9 667 0.07 7-11 -1860 0.58 - Low-rise and Components and Cladding designed by others, applied to the truss TC Vert 94.00 12- 7- 2 94.00 15- 2-12 0.7 <br /> Tributary Area = 40 sgft face providing lateral support for webs in TC Vert 84.00 15- 2-12 64.00 20- 0- 0 0.8 <br /> TB FORCE Ala HND CSI a es ane d creating shear wall TC Vert 104.00 20- 0- 0 104.00 21- 6- 0 0.6 <br /> 3-12 -1145 0.38 0.00 0.38 do to slot a hra loads. BC Vert 20.00 0- 0- 0 20.00 4- 9- 4 0.0 <br /> 12-5 -1145 0.38 0.00 0.38 ,o � NI�4-9-4 RC Vert 106.00 4- 9- 4 106.00 15- 2-12 0.6 <br /> AW FORCE CSI AN FORCE CSI 499-4 '�"'�` _' :i 20-0-0 BC vest 20.00 15- 2-12 20.00 20- 0- 0 0.0 <br /> 3-5 V 10.00 7- 4-14 10.00 12- 7- 2 0.0 <br /> 4-12 40 0.02 10-0-0 10-0-0 .Type... lbs X.Loc LL/TL Fastener <br /> 1 2 3 4 5 6 7 TC Vert 60.0 - 1- 6- 0 1.00 <br /> TC Vert 60.0 21- 6- 0 1.00 <br /> BC Vert 28.7 4- 9- 4 0.00 <br /> 12.00 -1� BC Vert 28.7 15- 2-12 0.00 <br /> RSX6 <br /> MAX DEFLECTION (span) <br /> L/798 MEM 9-10 (LZW) LC 1 <br /> 4X4 4X4 L= -0.30" D= -0.14" T- -0.43 <br /> Joint Locations <br /> MIR =0- 0- 0 7 20- 0- 0 <br /> ZX4 2X4 2 4- 9- 4 8 0- 0- 0 <br /> 12-0-0 12-1-12 3 7- 6-SO 9 4- 9- 4 <br /> SHIP 4 10- 0- 0 10 15- 2-12 <br /> 8-1-14 5 12- 5- 6 11 20- 0- 0 <br /> 6 15- 2-12 12 10- 0- 0 <br /> 6X8 6X8 <br /> I2-0-0 I2-0.0 <br /> 19 4 5-0-0 7X8 7X6 2X4 <br /> B2 <br /> W:508 W:508 <br /> 11:1787 11:1787 <br /> ' 29# 1t <br /> 2M_0 <br /> '8 9 10 11 <br /> 49=4 105-8 49_4 <br /> 49-4 15-2-12 20-0-0 <br /> TYPICAL PLATE:1.5X3 10/17/2014 <br /> All connector plates are Truswal 20 go.unless preceded by"W"for Wave 20 go.,"HS"for HS 20 go.,"S"for SS 18 go.from Alpine;or preceded <br /> by"MX"for TWMX 20 ga.or"H"for 16 ga.from Truswal,positioned per Joint Detail Reports available from Truswal software,unless noted. Scale:118"=1' <br /> WARNING Read all notes on this sheet and give a copy of it to the Erecting Contractor. Wght 220 WORK ORDER:Q261448 <br /> V I L LA U IVI E This design Is for an Individual building component not truss system.It has been based on epecilicadons provided by the component manufacturer Chk: CUST•SAWHORSE <br /> and done in accordance with the current versions of TPI and AFPA design standards.No responsibility Is assumed for dimensional accuracy.Dimensions 9 <br /> DS nr.SJS DUE DATE:10/17/14 <br /> are to be verliled by the component manufacturer and/or building designer prior to fabricallon.The building designer must ascertain that the loads <br /> utilized on this design meet or exceed the loading Imposed by the local building code and the particular application.The design assumes that the top chord TC Live 35.00 psf DurFacs L=1.15 P=1.15 <br /> Is laterally braced by the roof or floor sheathing and the bottom chord Is laterally braced by a rigid sheathing material directly attached,unless otherwise <br /> noted.Bracing shown Is for lateral support of components members only to reduce buckling length.This component shall not be placed In any TC Dead 7.00 psf Defl.Ratio: 240 <br /> emdreiamm that wen cause the moisture content of the wood to exceed 19%andlor cause connector plate corrosion.Fabricate,handle,install BC Live 0.00 psf O.C.Spacing 2-0-0 <br /> 2826 Lone Oak Circle,St.Paul,MN 55121 and brace this trues In accordance with the following standards:'Joint and Cutting Detail Reports'available as output from Truswal software, <br /> PH;651-454-3610 FAX;661.4544765 'ANSUTPI 1',V TCA V.Wood Truss Council of America Standard Design Responslbilltles,'BUILDING COMPONENT SAFETY INFORMATION- BC Dead 10.00 psf Design Spec IRC-2006 <br /> (SCSI)and SCSI SUMMARY SHEETS'by WTCA and TPL The Truss Plate Institute(TPO Is located at 218 N.Lee street Suite 31Z <br /> Alexandria,VA 22314.The American Forest and Paper Association(AFPA)Is located at 111119th street,NW,Ste 800•Washington,Dc 20936. TOTAL 52.00 psf Seqn T6.5.19- 56488 <br />