Laserfiche WebLink
16 <br /> 4.0 INSTALLATION <br /> EN •v .�'. omav <br /> NEVER INSTALL A SINGLE WALL SLIP SECTION OR SMOKE PIPE IN A CHASE STRUCTURE. <br /> THE HIGHER TEMPERATURE OF THIS SINGLE WALL PIPE MAY RADIATE SUFFICIENT HEAT TO <br /> COMBUSTIBLE CHASE MATERIALS TO CAUSE A FIRE. <br /> TO AVOID DANGER OF FIRE,ALL INSTRUCTIONS MUST BE STRICTLY FOLLOWED, INCLUDING <br /> THE PROVISION OF AIR SPACE CLEARANCE BETWEEN CHIMNEY SYSTEM AND ENCLOSURE.TO <br /> PROTECT AGAINST THE EFFECTS OF CORROSION ON THOSE PARTS EXPOSED TO THE WEATHER, <br /> WE RECOMMEND THAT THE CHASE TOP BE PAINTED WITH A RUST-RESISTANT PAINT. <br /> MAINTAIN A MINIMUM 2"(51mm)AIR CLEARANCE TO ALL PARTS OF THE CHIMNEY SYSTEM AT ALL <br /> TIMES.FAILURE TO MAINTAIN THIS 2"(50.8mm)AIR CLEARANCE WILL CAUSE A STRUCTURE FIRE. <br /> DETAILED INSTRUCTIONS FOR INSTALLATION OF THE CHASE TOP,STORM COLLAR AND <br /> TERMINATION CAP ARE PACKAGED WITH THESE PARTS. <br /> FIRESTOP SPACERS MUST BE USED WHENEVER THE CHIMNEY PENETRATES A CEILING/FLOOR <br /> AREA. <br /> THE CHIMNEY MUST BE SOUND AND FREE OF CRACKS.CLEAN YOUR CHIMNEY A MINIMUM OF TWICE A <br /> YEAR AND AS REQUIRED. <br /> 4.1 CHIMNEY <br /> NOTE;All venting connections must be in compliance with the chimney manufacturers installation <br /> instructions. <br /> This appliance was tested to CAN/ULC S610 and UL 127 Factory Built Fireplace Standards.This appliance <br /> has met the test criteria for Zero Clearance Installation to Combustible Surfaces and Certified to burn firewood <br /> only. <br /> Any chimney 10"(254 mm)or 12"(305 mm)diameter listed to CAN/ULC S610 and UL127 or to the following <br /> standards; CAN/ULC-S604 and CAN/ULC-S629 for Canada or UL-103 or UL-103HT for the United States may <br /> be installed. <br /> Installation of all types of factory-built chimney systems is to <br /> be in accordance with the chimney manufacturers installation <br /> instructions.An appropriate chimney manufacturers anchor base <br /> plate and anchor base plate gasket is required in order to initiate ANCHOR PLATE <br /> their system. Use the high temperature gasket,supplied, to <br /> seal between the anchor plate and the appliance top.Air cooled <br /> chimney systems are not recommended in colder climates. <br /> Complete installation instructions for Selkirk Ultra Temp Chimney <br /> for Canada and Ultra Temp Platinum Chimney for USA, refer to: _ -:- - - CE <br /> www.selkirkinc.com/products/chimney.aspx <br /> ANCHOR PLATE FOR A FACTORY <br /> A chimney venting the appliance shall not vent any other BUILT CHIMNEY <br /> appliance.The minimum overall chimney height from the top of the <br /> appliance is 15ft(4.6m).The maximum overall chimney height from the top of the appliance is 34ft(10.4m). <br /> Factory-built chimney systems for use in dwellings constructed for three or more families must be enclosed <br /> above the room in which the appliance is located.This enclosure must have a fire resistance rating equal to or <br /> greater than that of the floor or roof assembly through which they pass. <br /> The chimney should not be built with an offset angle in excess of 45° in Canada and 30°in USA. <br /> Ensure that minimum clearances are maintained. <br /> Portions of the chimney that extend through accessible spaces must always be encased to avoid personal <br /> contact with the chimney and thereby avoid damage to the chimney. <br /> The chimney must be supported at a maximum of 20ft(6.1m)intervals[approx.200 lbs/20 FT(90.7kg/6.1m)]. <br /> 63.9 <br /> When using 10"chimney,center anchor plate to appliance flue outlet <br /> W115-1642/04.15.16 <br />