Sprinkler system schematics
Orono
>
Property Files
>
Street Address
>
O
>
Old Crystal Bay Road North
>
0685 Old Crystal Bay Road North - 33-118-23-21-0002
>
Misc
>
Sprinkler system schematics
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:48:06 PM
Creation date
2/27/2018 12:25:36 PM
Metadata
Fields
Template:
x Address Old
House Number
685
Street Name
Old Crystal Bay
Street Type
Road
Street Direction
North
Address
685 Old Crystal Bay Road North
Document Type
Misc
PIN
3311823210002
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
85
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
PAGE 01 <br /> VIKING AUTOMATIC SPRINKLER CO. <br /> ST. PAUL , MN 551 12 <br /> 612-636-468_! <br /> HYDRAULIC DESIGN INFORMATION SHEET <br /> -------------- <br /> NAME - ORONO SCHOOL DATE - 072392 <br /> LOCATION - 685 OLD CRYSTAL BAY ROAD <br /> :BUILDING - MIDDLE SCHOOL SYSTEM NO. - ZONE #5 <br /> CONTRACTOR - VIf-MING AUTOMATIC SPRINKLER. CO CONTRACT NO. - 7653 <br /> CALCULATED BY - BRAD BECHEL DRAWING NO. - <br /> CONSTRUCTION: ( ) COMBUSTIBLE (X) NON-COMBUSTIBLE CEILING HEIGHT 23 '-011 <br /> OCCUPANCY - GYMNASIUM <br /> S (X )NFPA 13 ___-- (� ) LT.-HAZ .------ORD.HAZ .GP . ( ) 1 ( )2 (X )•:� ( )EX .HAZ . <br /> Y ( )NFPA 2-1 ( )NFPA 231C FIGURE 5-2.3 CURVE ORD GRP III <br /> S ( )OTHER <br /> T ( )SPECIFIC RULING MADE BY DATE <br /> M AREA OF SPRINKLER OPERATION 15oO SYSTEM TYPE <br /> DENSITY-GPM/Ft"2 .20 (X) WET 4 ) DRY <br /> D AREA PER SPRINKLER 101 .53 ( ) DELUGE ( ) PREACTION <br /> E HOSE ALLOWANCE GPM-INSIDE 0 SPRINKLER OR. NOZZLE <br /> S HOSE ALLOWANCE GPM-OUTSIDE 250 MAKE RELIABLE MODEL G <br /> I RACE`: SPRINKLER ALLOWANCE 0 SIZE 1/2" K-FACTOR 5 .62- <br /> G <br /> .62G ELEVATION AT HIGHEST OUTLET '22.0i? TEMPERATURE RATING 1.65 <br /> N NOTE <br /> CALCULATION GPM REQUIRED 595 .01 PSI REQUIRED 49 .02 AT HYDRANT <br /> SUMMARY C-FACTOR USED: OVERHEAD 12o UNDERGROUND 140 <br /> W WATER FLOW TEST: PUMP DATA: TANK OR RESERVOIR: <br /> A DATE OF TEST RATED CAP . CAP . <br /> T TIME OF TEST @ PSI ELEV. <br /> E STATIC (PSI ) 59.5 ELEV. <br /> R. RESIDUAL (PST. ) 20 WELL. <br /> FLOW (GPM) 2050 PROOF FLOW GPM <br /> S ELEVATION 9.66 <br /> P LOCATION AT HYDRANT OUTSIDE BUILDING <br /> P <br /> L SOURCE OF INFORMATION CALCULATED WATER. FLOW FROM FUTURE WATER TOWER BY <br /> Y B.R.A ENGINEER <br /> COMMODITY CLASS LOCATION <br /> C STORAGE HT . AREA AISLE W. <br /> 0 STORAGE METHOD: SOLID PILED % PALLETIZED % RACK % <br /> M (- ) SINGLE ROW ( ) CONVEN. PALLET ( ) AUTO. STORAGE ( ) ENCAP . <br /> R ( ) DOUBLE ROM ( ) SLAVE PALLET ( ) SOLID SHELF t ) NON <br /> S A ( ) MULT. ROW ( ) OPEN SHELF <br /> 0 K FLUE SPACING-- CLEARANCE:STORAGE TO CEILING <br /> R LONGITUDINAL TRANSVERSE <br /> G HORIZONTAL BARRIERS PROVIDED- <br /> E <br /> =h=r •fr,r l f-C- ! Tp,�_! _ -1 -ht(^ rW (t._f1i� r, - -�'I-10W (clPM i PRESSURE (PSI ) <br /> t t t T __ r, r L-.. , <br />