My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
sprinkler system info/inspections
Orono
>
Property Files
>
Street Address
>
O
>
Old Crystal Bay Road North
>
0685 Old Crystal Bay Road North - 33-118-23-21-0002
>
Land Use
>
sprinkler system info/inspections
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:48:06 PM
Creation date
2/22/2018 2:12:39 PM
Metadata
Fields
Template:
x Address Old
House Number
685
Street Name
Old Crystal Bay
Street Type
Road
Street Direction
North
Address
685 Old Crystal Bay Road North
Document Type
Land Use
PIN
3311823210002
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
15
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
1301 L'Orient Street <br /> St.Paul,Minnesota 55117 <br /> (651)558-3300 • (800)229-6263 <br /> AUTOMATIC SPRINKLER CO. Fax: (651)558-3310 <br /> Setting Ti;tee Standard,.. <br /> AGREEMENT AND REPORT OF INSPECTION <br /> SHEET 1 of 2-Use separate sheet for each building inspected #INSPECTION <br /> MINNESOTA LICENSE NO.CW5 <br /> REPORT TO 3,j q Q k :W, J u � �( BUIL�}DING OR LOCATION -5,04 t"-P <br /> STREET (_4:5 a l J C x-!y4 /,ti A4 u no-d/ INSPEC'T'OR /A 7- 640 <br /> CITY&STATE ©X a-10 � f1/1,J. DATE /y-s6,_d <br /> Owner hires Viking Automatic Sprinkler Company to conduct an inspection of the fire suppression system at the above location or building,and <br /> prepare a written report of that inspection for an agreed upon fee. As part of this agreement,owner agrees to terms and conditions on rear of form and <br /> will complete the Owner's Section of this document. <br /> Owner's Section(To be answered by Owner or Occupant) <br /> A. Explain any occupancy hazard changes since the previous inspection: i(J o/.1 CZ <br /> B. Describe fire protection modifications made since last inspection: �A 1 4) <br /> C. Describe any fires since last inspection: 4)t-;;,k) d <br /> D. When was the system piping last checked for stoppage,corrosion or foreign material? T) <br /> E. When was the dry-piping system last checked for proper pitch? wig <br /> F. Are dry valves adequately protected fr=_�Xl <br /> ? Ad <br /> Signature _4 — Date <br /> Inspector's Section(All responses reference current inspection) N/A=NOT APPLICABLE <br /> 1 General <br /> a. Is the building occupied?)Yes ❑No <br /> b. Are all systems in service?plyes ❑No <br /> c. Does there appear to be a minimum of 18 in.(457 mm)clearance between the top of thest rage and the sprinkler deflectors?>Yes ❑No <br /> d. Does the valve hose on the sprinkler system(s)appear to be satisfactory? ❑Yes ❑No i N/A <br /> 2 Control Valves(See Item 15) <br /> a. Do sprinkler system control valves appear to be in the appropriate open or closed position? A Yes ❑No <br /> b. Are control valves in the open position locked,sealed or equipped with a tamper switch?,)gYes ❑No <br /> 3 Water Supplies(See Item 16) �- <br /> a. Was a water flow test of main drain made at the sprinkler riser(s)? AC es ❑No <br /> 4 Tanks,Pumps,Fire Department Connections <br /> a. Are fire pumps,gravity tanks,reservoirs and pressure tanks in good condition and properly maintained? ❑Yes u No AQV/A <br /> b. Are fire department connections in satisfactory condition,couplings free,caps in place,and check valves tight? 91Yes ❑No ❑N/A <br /> Are they accessible and visible?*Yes n No ❑N/A <br /> 5 Wet Systems <br /> a. Are cold weather valves(O.S.&Y.)in the appropriate open or closed position?A.Yes ❑No n N/A <br /> b. Have antifreeze system solutions been tested? ❑Yes ❑No PN N/A <br /> c. Were the antifreeze test results satisfactory? ❑Yes ❑No &tN/A <br /> d. In areas protected by wet system(s),does the building appear to be properly heated in all areas,including blind attics and perimeter areas <br /> where accessible?p4Yes n No ❑N/A Do all exterior openings appear to be protected against freezing?rXYes ❑No n N/A <br /> 6 Dry System(See Items 11 to 13) <br /> a. Are dry valves(s)in service? ❑Yes ❑No (,4 N/A <br /> b. Are the air pressures and priming water levels in accordance with the manufacture's instructions? ❑Yes ❑No A4 N/A <br /> c. Has the operation of the air or nitrogen supplies been tested? ❑Yes ❑No p(N/A Are they in service? ❑Yes ❑No ,h�/A <br /> d. Were all know low points drained during this inspection? ❑Yes ❑No /FN/A <br /> e. Did quick-opening devices operate satisfactorily? ❑Yes ❑No vtQN/A <br /> f. Did the dry valve(s)trip properly during the trip pressure test? ❑Yes ❑No �N/A <br /> g. Did the heating equipment in the dry-pipe valve room(s)operate at time of inspection? ❑Yes ❑No CWN/A <br /> 7 Special Systems(See Item 14) <br /> a. Did the deluge or pre-action valves operate properly during testing? ❑Yes ❑No p4q/A <br /> b. Did the heat-responsive devices operate properly during testing? ❑Yes ❑No XN/A <br /> c. Did supervisory devices operate during testing? ❑Yes n No /dN/A <br /> 8 Alarms <br /> a. Did water motor(s)and gong(s)test satisfactorily? ❑Yes ❑No ,*N/A <br /> b. Did electric alarm(s)test satisfactory?X Yes ❑No ❑N/A <br /> c. Did supervisory alarm service test satisfactory?XYes ❑No ❑N/A <br /> 9 Sprinklers <br /> a. Do visible sprinklers appear to be free from corrosion,loading or obstruction to spray discharge?AYes ❑No <br /> b. Are sprinklers less than 50 years old? (Older sprinklers require sample testing)�Yes ❑No <br /> c. Are quick response and residential sprinklers less than 20 years old? (Older sprinklers require sample testing)Yes ❑No ❑N/A <br /> d. Is stock of spare sprinklers available? Yes ❑No <br /> e. Does the exterior condition of sprinkll system appear to be satisfactory?91-Yes ❑No <br /> f. Do visible sprinklers appear to be of proper temperature rating for their locations?�P Yes ❑No <br /> 10 Explain any"No"answers and comments: <br /> Signature: �2 _ _ Date: <br />
The URL can be used to link to this page
Your browser does not support the video tag.