Laserfiche WebLink
1301 L'Orient Street <br /> St.Paul,Minnesota 55117 <br /> (651)558-3300 • (800)229-6263 <br /> AUTOMATIC SPRINKLER CO. Fax: (651)558-3310 <br /> Setting Ti;tee Standard,.. <br /> AGREEMENT AND REPORT OF INSPECTION <br /> SHEET 1 of 2-Use separate sheet for each building inspected #INSPECTION <br /> MINNESOTA LICENSE NO.CW5 <br /> REPORT TO 3,j q Q k :W, J u � �( BUIL�}DING OR LOCATION -5,04 t"-P <br /> STREET (_4:5 a l J C x-!y4 /,ti A4 u no-d/ INSPEC'T'OR /A 7- 640 <br /> CITY&STATE ©X a-10 � f1/1,J. DATE /y-s6,_d <br /> Owner hires Viking Automatic Sprinkler Company to conduct an inspection of the fire suppression system at the above location or building,and <br /> prepare a written report of that inspection for an agreed upon fee. As part of this agreement,owner agrees to terms and conditions on rear of form and <br /> will complete the Owner's Section of this document. <br /> Owner's Section(To be answered by Owner or Occupant) <br /> A. Explain any occupancy hazard changes since the previous inspection: i(J o/.1 CZ <br /> B. Describe fire protection modifications made since last inspection: �A 1 4) <br /> C. Describe any fires since last inspection: 4)t-;;,k) d <br /> D. When was the system piping last checked for stoppage,corrosion or foreign material? T) <br /> E. When was the dry-piping system last checked for proper pitch? wig <br /> F. Are dry valves adequately protected fr=_�Xl <br /> ? Ad <br /> Signature _4 — Date <br /> Inspector's Section(All responses reference current inspection) N/A=NOT APPLICABLE <br /> 1 General <br /> a. Is the building occupied?)Yes ❑No <br /> b. Are all systems in service?plyes ❑No <br /> c. Does there appear to be a minimum of 18 in.(457 mm)clearance between the top of thest rage and the sprinkler deflectors?>Yes ❑No <br /> d. Does the valve hose on the sprinkler system(s)appear to be satisfactory? ❑Yes ❑No i N/A <br /> 2 Control Valves(See Item 15) <br /> a. Do sprinkler system control valves appear to be in the appropriate open or closed position? A Yes ❑No <br /> b. Are control valves in the open position locked,sealed or equipped with a tamper switch?,)gYes ❑No <br /> 3 Water Supplies(See Item 16) �- <br /> a. Was a water flow test of main drain made at the sprinkler riser(s)? AC es ❑No <br /> 4 Tanks,Pumps,Fire Department Connections <br /> a. Are fire pumps,gravity tanks,reservoirs and pressure tanks in good condition and properly maintained? ❑Yes u No AQV/A <br /> b. Are fire department connections in satisfactory condition,couplings free,caps in place,and check valves tight? 91Yes ❑No ❑N/A <br /> Are they accessible and visible?*Yes n No ❑N/A <br /> 5 Wet Systems <br /> a. Are cold weather valves(O.S.&Y.)in the appropriate open or closed position?A.Yes ❑No n N/A <br /> b. Have antifreeze system solutions been tested? ❑Yes ❑No PN N/A <br /> c. Were the antifreeze test results satisfactory? ❑Yes ❑No &tN/A <br /> d. In areas protected by wet system(s),does the building appear to be properly heated in all areas,including blind attics and perimeter areas <br /> where accessible?p4Yes n No ❑N/A Do all exterior openings appear to be protected against freezing?rXYes ❑No n N/A <br /> 6 Dry System(See Items 11 to 13) <br /> a. Are dry valves(s)in service? ❑Yes ❑No (,4 N/A <br /> b. Are the air pressures and priming water levels in accordance with the manufacture's instructions? ❑Yes ❑No A4 N/A <br /> c. Has the operation of the air or nitrogen supplies been tested? ❑Yes ❑No p(N/A Are they in service? ❑Yes ❑No ,h�/A <br /> d. Were all know low points drained during this inspection? ❑Yes ❑No /FN/A <br /> e. Did quick-opening devices operate satisfactorily? ❑Yes ❑No vtQN/A <br /> f. Did the dry valve(s)trip properly during the trip pressure test? ❑Yes ❑No �N/A <br /> g. Did the heating equipment in the dry-pipe valve room(s)operate at time of inspection? ❑Yes ❑No CWN/A <br /> 7 Special Systems(See Item 14) <br /> a. Did the deluge or pre-action valves operate properly during testing? ❑Yes ❑No p4q/A <br /> b. Did the heat-responsive devices operate properly during testing? ❑Yes ❑No XN/A <br /> c. Did supervisory devices operate during testing? ❑Yes n No /dN/A <br /> 8 Alarms <br /> a. Did water motor(s)and gong(s)test satisfactorily? ❑Yes ❑No ,*N/A <br /> b. Did electric alarm(s)test satisfactory?X Yes ❑No ❑N/A <br /> c. Did supervisory alarm service test satisfactory?XYes ❑No ❑N/A <br /> 9 Sprinklers <br /> a. Do visible sprinklers appear to be free from corrosion,loading or obstruction to spray discharge?AYes ❑No <br /> b. Are sprinklers less than 50 years old? (Older sprinklers require sample testing)�Yes ❑No <br /> c. Are quick response and residential sprinklers less than 20 years old? (Older sprinklers require sample testing)Yes ❑No ❑N/A <br /> d. Is stock of spare sprinklers available? Yes ❑No <br /> e. Does the exterior condition of sprinkll system appear to be satisfactory?91-Yes ❑No <br /> f. Do visible sprinklers appear to be of proper temperature rating for their locations?�P Yes ❑No <br /> 10 Explain any"No"answers and comments: <br /> Signature: �2 _ _ Date: <br />