My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Mech/Elect project manual-2000/Media center
Orono
>
Property Files
>
Street Address
>
O
>
Old Crystal Bay Road North
>
0685 Old Crystal Bay Road North - 33-118-23-21-0002
>
Misc
>
Mech/Elect project manual-2000/Media center
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:48:04 PM
Creation date
2/22/2018 2:03:43 PM
Metadata
Fields
Template:
x Address Old
House Number
685
Street Name
Old Crystal Bay
Street Type
Road
Street Direction
North
Address
685 Old Crystal Bay Road North
Document Type
Misc
PIN
3311823210002
Supplemental fields
ProcessedPID
Updated
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
296
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
2.05 FLOOR DRAINS <br /> A. General: Provide floor drains with cast-iron body,flashing flange and collar with inside caulk,bottom outlet for <br /> drains on grade,hubless,bottom outlet for drains above grade. <br /> B. All floor drams on grade shall be supplied with backwater valves unless otherwise noted. <br /> C. General: Provide floor drains of size as indicated on drawings;and,type,including features,as specified herein: <br /> (Typical units listed below are of Josam manufacture). <br /> D. Floor Drain Type FD-1: Coated cast iron combined floor drain and integral deep drum"P"trap with double <br /> drainage flange,weepholes,side outlet spigot connection,adjustable satin nikaloy round"Super-Flo"strainer with <br /> internal backwater valve. Josam Series No-30600-6AJ. <br /> 1. These drains are for use on grade in toilet rooms,showers,service sinks,kitchen,locker room and other <br /> finished areas. <br /> 2. Where floor drains with funnels are shown,provide Josam Series No.30600-E2-J floor drain with Nikaloy <br /> round funnel strainer with backwater valve. Field welded funnels on strainers are not acceptable. <br /> 3. Omit backwater valve in floor drain at dishwasher. <br /> PART 3: EXECUTION <br /> 3.01 EXAAMATION <br /> A. Verify all dimensions by field measurements. Verify that all drainage and vent piping and specialties may be <br /> installed in accordance with pertinent codes and regulations,the original design,and the referenced standards. <br /> B. Verify all existing grades,inverts,utilities,obstacles,and topographical conditions prior to installations. <br /> C. Examine rough-in requirements for plumbing fixtures and other equipment having drain connections to verify actual <br /> locations of piping connections prior to installation. <br /> D. Examine walls, floors, roof, and plumbing chases for suitable conditions where piping and specialties are to be <br /> installed. <br /> E. Review soil testing information provided to verify conditions are suitable for piping installations. <br /> F. Do not proceed until unsatisfactory conditions have been corrected. <br /> 3.02 PREPARATION OF FOUNDATION FOR UNDERGROUND BUILDING DRAINS <br /> A. Grade trench bottoms to provide a smooth,firm,and stable foundation,free from rock,throughout the length of the <br /> Pipe <br /> B. Remove unstable, soft, and unsuitable materials at the surface upon which pipes are to be laid and backfill with <br /> clean sand or pea gravel to indicated invert elevation. <br /> C. Shape bottom of trench to fit bottom'h of the circumference of pipe. Fill unevenness with tamped granular sand <br /> backfill. At each pipe joint dig bell holes to relieve the bell of the pipe of all loads, and to ensure continuous <br /> bearing of the pipe barrel on the foundation. <br /> 154124 No.99132-CP2 <br />