My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Mech/Elect project manual-2000/Media center
Orono
>
Property Files
>
Street Address
>
O
>
Old Crystal Bay Road North
>
0685 Old Crystal Bay Road North - 33-118-23-21-0002
>
Misc
>
Mech/Elect project manual-2000/Media center
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:48:04 PM
Creation date
2/22/2018 2:03:43 PM
Metadata
Fields
Template:
x Address Old
House Number
685
Street Name
Old Crystal Bay
Street Type
Road
Street Direction
North
Address
685 Old Crystal Bay Road North
Document Type
Misc
PIN
3311823210002
Supplemental fields
ProcessedPID
Updated
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
296
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
3.02 PIPE APPLICATIONS <br /> A. Install Schedule 40 steel pipe with threaded joints and fittings for 1%2 inch and smaller. <br /> B. Install Schedule 10 steel pipe with roll-grooved ends and grooved mechanical couplings for 2 inch and larger. <br /> 3.03 PIPING INSTALLATIONS <br /> A. Locations and Arrangements: Drawings (plans, schematics, and diagrams) indicate the general location and <br /> arrangement of piping systems. So far as practical,install piping as indicated. <br /> 1. Deviations from approved."Working Plans" for sprinkler piping, require written approval of the authority , <br /> having jurisdiction. Written approval shall be on file with the Architect prior to deviating for the approved <br /> "Working Plans." <br /> B. Install sprinkler piping to provide for system drainage in accordance with NFPA 13. <br /> C. Use approved fittings to make all changes in direction,branch takeoffs from mains,and reductions in pipe sizes. , <br /> D. Install unions in pipes 2 inch and smaller,adjacent to each valve. Unions are not required on flanged devices or in <br /> piping installations using grooved mechanical couplings. <br /> E. Install flanges or flange adaptors on valves,apparatus,and equipment having 2-1/2 inch and larger connections. <br /> F. Hangers and Supports: Comply with the requirements of NFPA 13 and NFPA 14. Hanger and support spacing and , <br /> locations for piping joined with grooved mechanical couplings shall be in accordance with the grooved mechanical <br /> coupling manufacturer's written instructions,for rigid systems. Provide protection from damage and where subject <br /> to earthquake in accordance with NFPA 13. ' <br /> G. Make connections between underground and above-ground piping using an approved transition piece strapped or <br /> fastened to prevent separation. <br /> H. Install mechanical sleeve seal at pipe penetrations in basement and foundation walls. Refer to Section 15050'Basic <br /> Mechanical Materials and Methods." <br /> I. Install test connections sized and located in accordance with NFPA 13 and local Authority with jurisdiction , <br /> complete with shutoff valve. Test connections may also serve as drain pipes. <br /> J. Install pressure gage on the riser or feed main at or near each test connection. Provide gage with a connection not ' <br /> less than 1/4 inch and having a soft metal seated globe valve, arranged for draining pipe between gage and valve. <br /> Install gages to permit removal,and where they will not be subject to freezing. <br /> K. Obstructions to sprinkler distribution pattern by permanent building components such as electric fixtures, ducts, <br /> pipes,unit heaters,partitions,enclosed spaces and small nitches,etc.and which require additional heads to provide <br /> required coverage shall be the design and installation responsibility of this contractor. <br /> L. Piping shall be installed parallel to building components wherever possible and shall be concealed in walls and <br /> above ceilings unless indicated otherwise on the plans. <br /> M. Pipes passing through masonry or concrete walls/floors and smoke/fire rated walls/floors shall be provided with , <br /> pipe sleeves set in place at the time of construction. Where core drilling is required, coordinate with structural <br /> engineer so as not to reduce the load carrying capacity of the structure. ' <br /> 15300-6 No.99132-CP2 ' <br />