My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Mech/Elect project manual-2000/Media center
Orono
>
Property Files
>
Street Address
>
O
>
Old Crystal Bay Road North
>
0685 Old Crystal Bay Road North - 33-118-23-21-0002
>
Misc
>
Mech/Elect project manual-2000/Media center
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:48:04 PM
Creation date
2/22/2018 2:03:43 PM
Metadata
Fields
Template:
x Address Old
House Number
685
Street Name
Old Crystal Bay
Street Type
Road
Street Direction
North
Address
685 Old Crystal Bay Road North
Document Type
Misc
PIN
3311823210002
Supplemental fields
ProcessedPID
Updated
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
296
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
F. Reinforcement Shapes and Plates: Unless otherwise indicated,provide galvanized steel reinforcing where installed <br /> on galvanized sheet metal ducts. For stainless steel ducts provide reinforcing of compatible materials. <br /> G. Aluminum Sheet: Where indicated,provide aluminum sheet complying with ASTM B 209, Alloy 3003, Temper <br /> H14. <br /> H. Tie Rods: Galvanized steel, 1/4-inch minimum diameter for 36-inch length or less;3/8-inch minimum diameter for <br /> lengths longer than 36 inches. <br /> I. Flexible Ducts: Spiral-wound spring steel with flameproof vinyl sheathing, or corrugated aluminum; complying <br /> with Ul 181. Class I. <br /> 1. Where installed in unconditioned spaces other than return air plenums, provide 1" thick continuous flexible <br /> fiberglass sheath with vinyl vapor barrier jacket. <br /> 2. Ducts in air return plenums must comply with Code flame and smoke requirements. <br /> 3. Manufacturers: Subject to compliance with requirements,provide flexible ductwork of one of the following: <br /> Wiremold 86A <br /> Wiremold 57LF <br /> Wiremold 57LFK <br /> Wiremold WC <br /> Wiremold WCK <br /> Thermaflex S.LP.10 <br /> Thermaflex M-K <br /> 2.02 DUCT LINER <br /> A. General: Comply with NFPA Standard 90A and TRVIA Standard AHC-101. <br /> B. Materials: ASTM C 1071,Type H,with coated surface exposed to airstream to prevent erosion of glass fibers. <br /> 1. Thickness: 1 inch. <br /> 2. Density. 1-1/2 pounds. <br /> 3. Thermal Performance: "K-Factor"equal to 0.28 or better,at a mean temperature of 75 deg F. <br /> 4. Fire Hazard Classification: Flame spread rating of not more than 25 without evidence of continued <br /> progressive combustion and a smoke developed rating of no higher than 50, when tested in accordance with <br /> ASTM C 411. <br /> 5. Liner Adhesive: Comply with NFPA Standard 90A and ASTM C 916. <br /> 6. Mechanical Fasteners: Galvanized steel,suitable for adhesive attachment,mechanical attachment,or welding <br /> attachment to duct. Provide fasteners that do not damage the liner when applied as recommended by the <br /> manufacturer,that do not cause leakage in the duct,and will indefinitely sustain a 50-pound tensile dead load <br /> test perpendicular to the duct wall. <br /> a. Fastener Pin Length: As required for thickness of insulation, and without projecting more than 1/8 inch <br /> into the airstream <br /> b. Adhesive For Attachment of Mechanical Fasteners: Comply with the "Fire Hazard Classification" of <br /> duct liner system <br /> 15891-4 No.99132-CP2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.