My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Mech/Elect project manual-2000/Media center
Orono
>
Property Files
>
Street Address
>
O
>
Old Crystal Bay Road North
>
0685 Old Crystal Bay Road North - 33-118-23-21-0002
>
Misc
>
Mech/Elect project manual-2000/Media center
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:48:04 PM
Creation date
2/22/2018 2:03:43 PM
Metadata
Fields
Template:
x Address Old
House Number
685
Street Name
Old Crystal Bay
Street Type
Road
Street Direction
North
Address
685 Old Crystal Bay Road North
Document Type
Misc
PIN
3311823210002
Supplemental fields
ProcessedPID
Updated
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
296
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
2.03 MODULAR AIR HANDLING UNITS <br /> A. General: <br /> 1. General Description: Factory assembled, consisting of fans, motor and drive assembly, coils, damper, <br /> plenums,filters,drip pans,and mixing dampers. <br /> 2. Types:Central-station air-handling units included in this project are of the following types: <br /> a. Draw-through. <br /> 3. Motor and Electrical Components: Refer to Division 15 Section 15030 Electrical Requirements for <br /> Mechanical Equipment. <br /> B. Cabinet: <br /> 1. Materials: Formed and reinforced double wall galvanized steel panels(the inner wall shall be perforated at the <br /> fan section and solid at all other sections), fabricated to allow removal for access to internal parts and <br /> components,with joints between sections sealed. <br /> a. Medium and high-pressure units shall be constructed with additional bracing and supports. Units rated <br /> at 5.5 inches w.g. and higher shall connected to accessories sections with double-thickness neoprene- <br /> coated flexible connection. <br /> 2. Insulation. Comply with NFPA Standard 90A "Standard for the Installation of A# Conditioning and <br /> Ventilating Systems,"for insulation. <br /> a. Type: Coated,glass-fiber insulation, 1 inch thick and having a minimum density of 1-1/2 pcf. <br /> b. Location and Application: Factory applied with adhesive and mechanical fasteners to the internal surface <br /> of section panels downstream from and including the cooling coil section. <br /> 3. Access Panels and Doors: Same materials and finishes as cabinet and complete with hinges,latches,handles, <br /> and gaskets. <br /> a. Fan section shall have inspection and access panels and doors sized and located to allow periodic <br /> maintenance and inspections. <br /> 4. Single-Wall Drain Pans: IAQ type double sloped drain pan formed of galvanized sheet steel. Fabricate pans <br /> in sizes and shapes to collect condensate from cooling coils (including coil piping connections and return <br /> bends) and humidifiers when units are operating at the maximum cataloged face velocity across the cooling <br /> coil. F <br /> a. Drain connections: The pan shall drain to the side of the unit nearest to the floor drain. Verify the <br /> location on the plans. Construct and install pan to provide adequate pitch to drain. <br /> b. Pan top surface coating: Elastomeric compound. <br /> c. Units with stacked coils shall have an intermediate drain pan or a drain trough to collect condensate from <br /> top coil. <br /> C. Fans Section: <br /> 1. Testing Requirements: The following factory tests are required: <br /> 158547 No.99132-CP2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.