My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Construction project manual-2000/Media center
Orono
>
Property Files
>
Street Address
>
O
>
Old Crystal Bay Road North
>
0685 Old Crystal Bay Road North - 33-118-23-21-0002
>
Misc
>
Construction project manual-2000/Media center
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:48:02 PM
Creation date
2/22/2018 1:41:15 PM
Metadata
Fields
Template:
x Address Old
House Number
685
Street Name
Old Crystal Bay
Street Type
Road
Street Direction
North
Address
685 Old Crystal Bay Road North
Document Type
Misc
PIN
3311823210002
Supplemental fields
ProcessedPID
Updated
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
271
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SECTION 08100 <br /> STEEL DOORS AND FRAMES <br /> PART 1: GENERAL <br /> 1.01 APPLICABLE DOCUMENTS <br /> A. Bidding Requirements, Conditions of the Contract and pertinent portions of Sections in Division One of these <br /> Specifications apply to the Work of this Section. <br /> 1.02 SUMMARY <br /> A. Section includes: <br /> 1. All hollow metal doors,door frames and borrowed light frames. <br /> B. Related work specified in other sections: <br /> 1. Grouting of frames,anchors-Section 04200. <br /> 2. Finish hardware Section 08700. <br /> 3. Glazing:Section 08800. <br /> 4. Painting-Section 09900. <br /> 1.03 QUALITY ASSURANCE <br /> A. Provide doors and frames complying with the SDI Standard 100-"Recommended Specifications Standard Steel <br /> Doors and Frames"and as herein specified. <br /> B. Obtain hardware templates from hardware supplier (Section 08700) and obtain necessary hardware for factory <br /> application. <br /> C. Where noted on Door Schedule,provide nationally recognized testing agency label of proper classification. Label <br /> requirements take precedence over conflicting details.Advise the Architect of any conflict before fabricating work <br /> on that item is started. <br /> 1.04 SUBMITTALS <br /> A. Submit complete working drawings showing all features of construction and anchorage, locations and details of <br /> field splices. Coordinate with any special conditions of anchorage. Submit door schedule on shop drawings <br /> indicating relationship of door,number of room, number and function of door, such as Corridor A-13 to Lavatory <br /> A-14. <br /> B. Submit documentation for UL 10C or other approved testing agency stating doors have passed UBC Standard 7-2. <br /> C. Submit in accordance with Section 01300. <br /> 1.05 PRODUCT PROTECTION <br /> A. Deliver doors and frames in suitable crating or packaging to prevent damage in transit and storage. <br /> 08100-1 No.99132-CP2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.