My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Construction project manual-2000/Media center
Orono
>
Property Files
>
Street Address
>
O
>
Old Crystal Bay Road North
>
0685 Old Crystal Bay Road North - 33-118-23-21-0002
>
Misc
>
Construction project manual-2000/Media center
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:48:02 PM
Creation date
2/22/2018 1:41:15 PM
Metadata
Fields
Template:
x Address Old
House Number
685
Street Name
Old Crystal Bay
Street Type
Road
Street Direction
North
Address
685 Old Crystal Bay Road North
Document Type
Misc
PIN
3311823210002
Supplemental fields
ProcessedPID
Updated
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
271
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
B. Point all joints, including scores, of glazed masonry units with colored pointing mortar. Tool joints concave ' <br /> smooth. <br /> C. Thoroughly clean exposed masonry. Before applying any cleaning agent to entire wall,apply to sample wall area of ' <br /> approximately 20 sq.ft.in location approved by Architect. Do not proceed with cleaning work until sample area is <br /> approved.Use approved cleaning material,method on remaining wall area. <br /> D. If stiff brushes, water do not suffice clean the surface on which no green efflorescence appears with Sure-Klean ' <br /> Vana-Trol as manufactured by Pro So Co.,Inc. <br /> E. Remove"problem" stains as follows with the as specified formulations of Pro So Co.,Inc.,or equal: ' <br /> 1. Green Efflorescence-"Sure-Klean No.800 Stain Remover". <br /> 2. Tar,Asphalt-"Sure-Klean Asphalt&Tar Remover". , <br /> 3. Ferrous Stains-"Sure-Klean Ferrous Stain Remover". <br /> F. Do not use acid solutions for cleaning masonry units unless specifically approved by Architect. <br /> G. Clean off loose mortar,remove stains from concrete masonry units. <br /> H. Schedule,complete cleaning work as soon as possible;in any event, before Owner's signage work is commenced. <br /> 3.11 FIELD QUALITY CONTROL <br /> A. Special Structural Testing and Inspection <br /> 1. Special Structural Testing and Inspection shall be performed by qualified parties as specified herein, and in ' <br /> accordance with the provisions of Section 01410. <br /> 2. Personnel Qualifications , <br /> a. Special Inspector-Technical <br /> 1.) Technical I - ACI Certified Grade I Technician. Inspector shall be employed by a testing ' <br /> laboratory,under the direct supervision of a registered civil/structural engineer. <br /> 2.) Technical II - ACI Certified Grade II Inspector. Inspector shall be employed by a testing ' <br /> laboratory,under the direct supervision of a registered civil/structural engineer. <br /> 3.) Technical III-A civil/structural engineer regularly engaged in this type of work,with a minimum of ' <br /> 4 years experience and registered in the State in which the project is located and is an employee of a <br /> qualified and approved testing laboratory. The registered engineer shall review and approve all <br /> reports- <br /> 4.) <br /> eports 4.) Testing laboratory shall have C.C.R.L.certification at the National Bureau of Standards. <br /> 3. The Owner will employ a Special Inspector for the following tests: ; <br /> a. Concrete masonry prism test for compressive strength according to ASTM E447-Method B. Conduct <br /> one set of three prisms at the start of construction and for each 5,000 square feet of block installed. ' <br /> Qualifications: Technical 11. <br /> END OF SECTION 04200 ' <br /> 04200-8 No.99132-CP2 , <br />
The URL can be used to link to this page
Your browser does not support the video tag.