My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Construction project manual-2000/Media center
Orono
>
Property Files
>
Street Address
>
O
>
Old Crystal Bay Road North
>
0685 Old Crystal Bay Road North - 33-118-23-21-0002
>
Misc
>
Construction project manual-2000/Media center
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:48:02 PM
Creation date
2/22/2018 1:41:15 PM
Metadata
Fields
Template:
x Address Old
House Number
685
Street Name
Old Crystal Bay
Street Type
Road
Street Direction
North
Address
685 Old Crystal Bay Road North
Document Type
Misc
PIN
3311823210002
Supplemental fields
ProcessedPID
Updated
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
271
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
G. Tie securely or use splice devices to prevent displacement of splices during concrete placement. <br /> H. Support and wire together reinforcing to prevent displacement by construction loads and placing of concrete. <br /> Welding of cross bars is not permitted for assembly of reinforcement. On grade,supporting concrete brick may be <br /> used. Over formwork use approved bar chairs and spacers. <br /> I. Unless approved by the Architect,do not bend reinforcement after being partially embedded in hardened concrete. <br /> J. Show lap and spacing of reinforcing on shop drawings. <br /> K. Embed conduit and pipes after placing reinforcing steel in a manner that will not impair the strength of <br /> construction. Do not embed conduit and pipes larger in outside diameter than one-third thickness of slab, wall or <br /> beam,nor space closer than 3 diameters o.c.without approval of the Architect. For conduit or pipe which parallels <br /> principal reinforcement maintain 1-1/2"clear from reinforcing. <br /> 3.02 CONCRETE COVER <br /> A. For minimum concrete protection over reinforcement see ACI 318 Chapter 7 and as detailed on the Drawings. <br /> 3.03 FIELD QUALITY CONTROL <br /> A. Special Structural Testing and Inspection <br /> 1. Special Structural Testing and Inspection shall be performed by qualified parties as specified herein, and in <br /> accordance with the provision of Section 01410. <br /> 2. Personnel Qualifications: <br /> a. Special Inspector-Technical: Not used. <br /> b. Special Inspector-Structural: <br /> 1.) Structural I - Graduate civillstructural engineer, or other personnel acceptable to the Structural <br /> Engineer of Record (SER), with the experience in the design of structural systems of this type. <br /> Inspection shall be performed under the direct supervision of a registered civil/structural engineer. <br /> 2.) Structural H-Civil/structural engineer regularly engaged in the design of structural systems of this <br /> type,registered in the state in which the project is located. The registered engineer shall review and <br /> approve all inspection reports. <br /> 3. The Owner will employ a Special Inspector for the following inspections: <br /> a. Inspect reinforcement in all cast in place concrete, excluding slabs on grade,footings without transverse <br /> reinforcement,and topping slabs. Qualifications: Structural I. Verify the-following: <br /> 1.) Reinforcing bar grade. <br /> 2.) Reinforcing bars are free of oil,dirt,excessive rust,and damage. <br /> 3.) Reinforcing bars are adequately tied, chaired, and supported to prevent displacement during <br /> concrete placement. <br /> 4.) Proper clear distances between bars and to surfaces of concrete. <br /> 5.) Reinforcing bar size and placement. <br /> 6.) Bar laps for proper length and stagger. <br /> 7.) Bar bends for minimum diameter,slope and length. <br /> 8.) Mechanical splices are placed in accordance with the plans, specifications and reviewed shop <br /> drawings. <br /> END OF SECTION 03200 <br /> 03200-3 No. 99132-CP2 <br />