KDM-R2 Controls and Indicators mode fiber,and media conversion models are available. See <br /> Program Keypad:QWERTY type(keyboard layout). DN-60454. <br /> 12 LED Indicators: Power; Fire Alarm; Pre-Alarm; Security; RPT-W, RPT-F, RPT-WF: Standard-network repeater board <br /> Supervisory; System Trouble; Signals Silenced; Points Dis- with wire connection (RPT change <br /> multi-mode fiber connection <br /> abled;Control Active;Abort;Pre-Discharge;Discharge. (RPT F), or allowing a change in media type between wire <br /> and fiber(RPT-WF).Not used with high-speed networks.See <br /> Keypad Switch Controls:Acknowledge/Scroll Display; Sig- DN-6971. <br /> nal Silence;Drill;System Reset;Lamp Test. ONYXWorks: UL-listed graphics PC workstation, software, <br /> LCD Display:80 characters(2 x 40)with long-life LED back- and computer hardware. See DN-7048 for specific part num- <br /> light. bers. <br /> Product Line Information NFN-GW-EM-3:NFN Gateway,embedded.See DN-60499. <br /> NWS-3:NOTI•FIRE•NETrm Web Server.See DN-6928. <br /> • "Configuration Guidelines"on page 4 <br /> • "Networking Options"on page 4 CAP-GW: Common Alerting Protocol Gateway. See DN- <br /> 60576. <br /> • "Auxiliary Power Supplies and Batteries"on page 4 VESDA-HLI-GW: VESDAnet high-level interface gateway. <br /> • "Audio Options"on page 4 See DN-60753. <br /> • "Compatible Devices,EIA-232 Ports"on page 4 LEDSIGN-GW: UL-listed sign gateway.Interfaces with classic <br /> • "Compatible Devices,EIA-485 Ports"on page 4 and high-speed NOTI•FIRE•NET networks through the NFN <br /> • "Compatible Intelligent Devices"on page 5 Gateway.See DN-60679. <br /> • "Enclosures,Chassis,and Dress Plates"on page 5 OAX2-24V: UL-listed LED sign, used with LEDSIGN-GW. <br /> • "Other Options"on page 6 See DN-60679. <br /> CONFIGURATION GUIDELINES AUXILIARY POWER SUPPLIES AND BATTERIES <br /> The NFS-320 system ships assembled,• description and ACPS-610:6.0 A or 10.0 A addressable charging power sup- <br /> some options follow. See Enclosures, Chassis, and Dress ply.See DN-60244. <br /> Plates"on page 5 for information about mounting peripher- APS2-6R• Auxiliary Power Supply. Provides up to 6.0 <br /> als. amperes of power for peripheral devices. Includes battery <br /> NOTE:Stand-alone and network systems require a main display. input and transfer relay, and overcurrent protection. Mounts <br /> On stand-alone systems,the panel's keypad provides the required on two of four positions on a CHS-4L or CHS-4 chassis. See <br /> display. On network systems (two or more networked fire panel DN-5952. <br /> nodes), at least one NCA-2, NCS, or ONYXWorks annunciation <br /> device is required.(For NCA-2,see DN-7047.) FCPS-24S6/S8 Remote 6 A and 8 A power supplies with <br /> NFS-320:The standard,factory-assembled NFS-320 system battery charger.See DN-6927. <br /> includes the following components: one control panel BAT Series: Batteries.NFS-320 uses two 12 volt, 18 to 200 <br /> mounted on chassis(120 V operation—ships with ground- AH batteries. See DN-6933. <br /> ing cable, battery interconnect cables, and document kit); AUDIO OPTIONS <br /> includes integral power supply mounted to the main circuit <br /> board;one primary display KDM-R2 keypad/display;and one NFC-50/100: 25 watt, 25 VRMS, emergency Voice Evacua- <br /> cabinet for surface or semi-flush mounting. Purchase batter- tion Control Panel (VECP) with integral commercial micro- <br /> ies separately. One or two option boards may be mounted phone, digital message generator, and Class A or Class B <br /> inside the NFS-320 cabinet,additional option boards can be speaker circuits.See DN-60772. <br /> used in remote cabinets. (Non-English versions also avail- COMPATIBLE DEv/CES,EIA 232 PORTS <br /> able.NFS-320-SP,NFS-320-PO.) <br /> PRN-6:80-column printer.See DN-6956. <br /> NFS-32OR:Same as NFS-320,but in red enclosure. <br /> VS4095/5: Printer, 40-column, 24 V. Mounted in external <br /> NFS-320C: Based on NFS-320 above. NFS-320C supports backbox. See DN-3260. <br /> installation of an optional ACM-series annunciator in the <br /> same cabinet.UL-and ULC-listed. (Non-English version also DPI-232: Direct Panel Interface, specialized modem for <br /> available:NFS-320C-FR.)For NFS-320C,see DN-60085. extending serial data links to remotely located FACPs and/or <br /> NFS-320CR:Same as NFS-320C but in a red enclosure. For peripherals;mount on NFS-320 chassis.See DN-6870. <br /> NFS-320C,see DN-60085. COMPATIBLE DEvICEs,EIA-485 PORTS <br /> NFS-320E• Same as NFS-320, but with 240 V operation. ACM-24AT:ONYX Series ACS annunciator–up to 96 points <br /> (Non-English versions also available. NFS-320E-SP, NFS- of annunciation with Alarm or Active LED,Trouble LED, and <br /> 320E-PO.) switch per circuit.Active/Alarm LEDs can be programmed(by <br /> powered-up switch selection) by point to be red, green, or <br /> TR-320:Trim ring for the NFS-320 cabinet. yellow;the Trouble LED is always yellow.See DN-6862. <br /> NETWORKING OPTIONS AEM-24AT:Same LED and switch capabilities as ACM-24AT, <br /> NCM-W, NCM-F: Standard Network Communications Mod- expands the ACM-24AT to 48, 72, or 96 points. See DN- <br /> ules. Wire and multi-mode fiber versions available. See DN- 6862- <br /> 6661. ACM-48A:ONYX Series ACS annunciator–up to 96 points <br /> HS-NCM-W/MF/SF1WMF/WSF/MFSF• High-speed Network of annunciation with Alarm or Active LED per circuit.Active/ <br /> Communications Modules. Wire, single-mode fiber, multi- Alarm LEDs can be programmed (by powered-up switch <br /> Page 4 of 8—DN-7112.J•12/20/2013 <br />