-2- <br /> 3. Members are nailed together with 16 penny power gun nails. <br /> At the intersection of the lower chord members, a block has <br /> been installed between the two chords to tie them together <br /> since they are not in adjacent planes. <br /> 4. A structural engineering analysis was completed by me using <br /> design loads as required by the Minnesota State Building Code. <br /> The analysis indicated that the truss members are adequate in <br /> size. The connections between the members require 6 - 16 penny <br /> power nails each connection between chord members except at <br /> the ridge existing nailing is adequate. At the block member <br /> 6 nails are required from each side into the block member to <br /> adequately transfer the load between the two bottom chords. <br /> 5. The owner was directed to complete this work in accordance with <br /> this document. <br /> 6. The building inspection department of Orono was informed of <br /> this information and will provide follow-up inspections as <br /> required. <br /> SUMMARY <br /> 7. Based on the above information, the scissors truss as constructed <br /> with connections as noted is structurally adequate and meets the <br /> design requirements of the Minnesota State Building Code. <br /> If you have any questions, please contact me. <br /> Sincerely, <br /> John H. Dahlmeier, P.E. <br /> Registration No. 9212 <br /> JHD:gs / <br /> cc: City of Orono V <br /> I hereby certify that this plan, <br /> specification or report was prepared <br /> by me or under my direct supervision <br /> and that I am a duly registered <br /> professional engineer under the laws <br /> of the State of Minnesota. <br /> nnesota Registration No. 9212 <br />