Rusty Olson's--Soil and Percolation Testing <br /> Joseph J. Olson--MPCA License #810 <br /> 11481 Riverview Rd. NE, Hanover, MN 55341 <br /> (763) 498-8779 fax (763) 498-8290 <br /> May 2, 2002 <br /> Brad Pass <br /> Proposed Lot 1, Idyllvale Farm <br /> Orono,Henn. Co. <br /> This on-site Sewage Treatment System is partially designed for a Type 1,five-bedroom home in <br /> accordance with the Minnesota Pollution Control Agency Chapter 7080 and local ordinances. <br /> Once a house size and location are chosen this design can be completed. <br /> The soils on this site are SCS soils mapped—KkC-Kilkenny Loam. The seasonally saturated soils were <br /> located at 14"-20" (mottled soil). Due to the seasonally saturated soils,a pressurized Mound System will <br /> need to be installed to treat septic eluent. The bottom of the treatment area must be located at least 3' <br /> above the saturated soils. <br /> The soils at a depth of 12" have a percolation rate averaging 4 MPI. <br /> A pumping chamber will need to be installed to lift the eluent to the treatment area. The power supply <br /> and switches must be located outside the manhole and pumping chamber in a weatherproof enclosure. A <br /> warning device must be installed with a light and sound device;this is in case of a pump failure. <br /> Keep all hea-yj equipment off of the proposed treatment areas before and after construction The <br /> treatment area should be marked off before construction This Design is not valid&the System will <br /> freed to be relocated if to be relocated if failure to protect the areas imposed for On-Site Sewage <br /> Treatment occurs, <br /> Nothing other than gray water, (laundry, showers, ect.)human water&toilet tissue should be disposed of <br /> into the septic tanks. Garbage disposals are not recommended. Additives must no be used, they may <br /> cause harmful damage to your septic system. It is recommended that you pump the tank every year for 1 <br /> tank. Every two years for two tanks. <br /> Sincerely. <br /> CITY OF ORONO <br /> SEPTIC P RMI P N REVIEW <br /> 7oseph 1. Olson INSPECTOR ��^�^ <br /> DATE-1—M-01 PERMIT NO. <br /> ® APPROVED AS SUBMITTED <br /> ® APPROVED WITH CORRECTIONS AS NOTED <br /> NOT APPROVED-CORRECT&RESUBMIT <br /> These comments are for your information. All work shall be(luno <br /> In full compliance with all applicable septic and zoning code. <br /> Requirements including items not specifically noted in this review. <br /> KEEP THIS PLAN SET ON SITE AT ALL TIMLS <br />