Laserfiche WebLink
F-17 <br /> '7 • FTEMY SELECTION PROCEDURE <br /> END PERFORATION OF A PERFORATED LITERAL <br /> A. Determine pump capacity: d�C~ <br /> Gravity Distribution T +I <br /> 1. Minimum suggested is 600 gallons per hour(10 gpm)to stay ahead of d w.».,..F..r I-ar- <br /> water use rate. .`'M's�` .VAW 1'=«"e <br /> r.e"WIPM-) <br /> 2. Maximum suggested for delivery to a drop box of a home system is 2,700 "Umd <br /> gallons per hour(45 gpm)to prevent build-up of pressure in drop box. y;M�a � .Ed" <br /> Pressure Distibution `""5.4 L,. <br /> 3.a. Select number of perforated laterals 3 <br /> b. Select perforation spacing=.3_feet. �Pte; L.Y. <br /> c- Subtract 2 ft.from the rock layer length. <br /> -2ft.= L feet. <br /> d. Determine the number of spaces between perforations. <br /> Length perf.spacing=S,j,ft.+ -t, ft._�.spaces Required Perforation Discharge <br /> e. Ztz spaces+1= �)-*:%_p <br /> erforations/lateral in p U-per xW-te W- <br /> f. Multiply perforations per lateral by number of laterals to DIV d e 4I"tet34e ft&PW <br /> get total number of perforations. x e,l=_ 7 perforations. (feet) <br /> g W x 5s"F-1_ �� 1.0a 0.56 0.74 <br /> SELECrE"D PUMP CAPACITY 1, `7_gpm 2.Ob 0.80 1.04 - <br /> B.Determine head requirements: a.Use for single family homes <br /> 1. Elevation difference between pump and point of discharge. b.Use for all other applications <br /> I feet <br /> 2. If pumping to a pressure distribution system,five feet for pressure <br /> required at manifold if gravitys tem,zero. <br /> feet <br /> 3. Friction loss <br /> a. Enter friction loss table with gpm and pipe diameter. Pipe Length , <br /> Read friction loss in feet per 100 feet from table. Point of Diwbmzc <br /> F.L= D., ft./100 ft of pipe ............................. o.0 <br /> b. Determine total pipe length from pump to discharge Elevation Difference <br /> point. Add 25 percent to pipe length for fitting P 'dy <br /> loss,or use a fitting loss chart. Equivalent pipe <br /> length-1.25 times pipe length= F-18b <br /> 1 10 x 1.25= as S feet 1,5 inch 2.0 inch 3.0 inch <br /> c. Calculate total friction loss by multiplying gpm Maim las pa IOOR of pipe <br /> friction loss in ft/100 ft by equivalent pipe length. 10 0.69 0.20 <br /> Total friction loss- 'Aa,S x a.,I= +100= feet 12 0.96 0.28 <br /> 4. Total head required is the sum of elevation difference, 14 1.28 0.38 <br /> special head requirements,and total friction loss. 16 1.63 0.48 <br /> 18 2.03 0.60 <br /> 20 2.47 0.73 0.11 <br /> II. + Sr + 40 25 3.73 1.11 0.16 <br /> (1) (2) (3c) 30 5.23 1.55 0.23 <br /> 35 7.90 2.06 0.30 <br /> TOTAL HEAD a 40 11.07 2.64 0.39 <br /> feet_ 45 14.73 3.28 0.48 <br /> 50 3.99 OM <br /> 55 4.76 0.70 <br /> G Pump selection 60 5.60 0.82 <br /> 1. A pump must be selected to deliver at least <br /> � -; gpm (Step A)with at least a7 feet of total head(Step B). <br />