My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Re: structural design
Orono
>
Property Files
>
Street Address
>
N
>
North Shore Drive West
>
0070 North Shore Drive West - 06-117-23-22-0020
>
Correspondence
>
Re: structural design
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 3:15:00 PM
Creation date
2/5/2018 1:36:43 PM
Metadata
Fields
Template:
x Address Old
Address
0070 North Shore Dr W
Document Type
Correspondence
PIN
0611723220020
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
9
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• DEFINITION:A RETAINING WALL 15 ANY FOUN- MARK/SIZE&REINFORCING <br /> DA11ON WALL STRUCTURAL NOTES PRESSURE AT THEN oRACED AGAINST 501E F20 1'-8'X V-8'X 10" DEEP WITH (2) #4 BOT- <br /> FOUNDATION WALLS, FOOTINGS, P/C PLANK TOM BARS EACH WAY <br /> MASONRY FOUNDATION WALLS: F24 2'-0'X Z-O*X 10"DEEP WITH (2)14 BOT- <br /> BOLDENOW RESIDENCE TDM BARS EACH WAY <br /> 70 NORTH SHORE DRIVE FW12 12" FULL HEIGHT BASEMENT FOUN- <br /> QRONO MN DATION WALL: SEE DETAIL FW12 FOR F40 3'-4'X 3'-4'X 10'DEEP WITH (5)#4 BOT- <br /> REINFORCING AND OTHER INFORMATION. TOM BARS EACH WAY <br /> ARCHISTRUCTURES #0105-6 F4$ 4'-0"XC-O'X 12"DEEP WITH (5)#4 BOT- <br /> SHALLOW FOUNDATION WALLS: TOM BARS EACH WAY <br /> F56 4'-8'X 4'-8'X 12'DEEP WITH (6)94 BOT- <br /> SEE ACCOMPANYING LETTER OF CERTIFICATION. CONSTRUCT 51MILAR TO FW12 WALL, EXCEPT TOM BARS EACH WAY <br /> SEE'ROOF,FLOOR AND WALL FRAMING"NOTES PROVIDE FOOTING R AT MINIMUM FROST F63 5'-3'X 5'-3'X 12'DEEP WITH (7) 94 BOT- <br /> FOR ADDITIONAL INFORMATION. LEVEL ONLY.NO REINFNFORCCININ G REQUIRED. TOM BARS EACH WAY <br /> • SW12:12'THICK FOUNDATION WALL. <br /> SOIL OUALITY: PIER/ FOOTINGS: <br /> MASONRY SQUARE PIERS: <br /> FOOTINGS HAVE BEEN DESIGNED TO BEAR ON CONCRETE STRENGTH:MIN.F'c=3000 PSI. <br /> 5AT15FAC71ORY SOILS, DEFINED A5 GOOD DOWEL VERTICAL REINFORCING 6'INTO FOOTING. PROVIDE 12' DIAMETER AUGURED ROUND PIER <br /> QUALITY, WELL-DRAINING, GRANULAR 501L PIER TYPES ARE NOTED BY THE FOLLOWING (OR 50NOTU13E FORM) WITH (1) #4 VERTICAL <br /> CAPABLE OF A MINIMUM 2250 P5F DE51GN MARKS ENCLOSED WITHIN A HEXAGON: BAR FULL HEIGHT OF FOOTING. BELL OUT THE <br /> PRESSURE. M12 12'BY 12' MASONRY PIER: (1) #4 VERT- BOTTOM OF THE PIER AT 45 DEGREE ANGLE TO <br /> ICAL BAR FULL HEIGHT. FORM AN 8' HIGH FOOTING WITH OVERALL <br /> • FOOTINGS SHALL NOT BEAR BELOW WATER <br /> TABLE. DIAMETER AS SHOWN ON PLAN. <br /> SOIL VERIFICATION: CONTRACTOR SHALL VE- MASONRY WALL PIERS: FOOTING BEARING: <br /> RIFY SOIL QUALITY TO BE AS DESCRIBED ABOVE. CENTER WALL PIER IMMEDIATELY BELOW BEAM <br /> IF IN DOUBT,INFORM OWNER. OR COLUMN BEARING. DOWEL ALL VERTICAL FROST PROTECTION: FOOTING BEARING ELE- <br /> OWNER'S ACTION: IN THE ABSENCE OF A REINFORCING BARS 6' INTO FOOTING. PIER VATION SHALL BE PER MINNESOTA STATE BUIL- <br /> 501L REPORT,THE OWNER BEARS PRIMARY RE- TYPES ARE NOTED BY THE FOLLOWING MARKS DING CODE 1300.5500.INCLUDING: <br /> SPONSIBILITY FOR ACTUAL SOIL CONDITIONS. IF ENCL05ED WITHIN A HEXAGON. • ZONE 2:BEAR 3'-6"BELOW FINISH GRADE. <br /> SOIL QUALITY 15 IN DOUBT,IT IS RECOMMENDED <br /> THAT OWNER OBTAIN THE SERVICES OF A RE- M1 PROVIDE(1)94 VERTICAL BAR IN (1) FULL • FROST EXPOSURE: CONTRACTOR TO PRO- <br /> G15TERED 501L ENGINEER.OWNER SHALL BEAR HEIGHT GROUTED MASONRY WALL CORE. VIDE ADEQUATE MEANS TO PROTECT FOOT- <br /> ANY ADDITIONAL COSTS FOR 501L REPORT, M4 PROVIDE (4) #4 VERTICAL BARS IN (2) INGS AND ALL OTHER STRUCTURE FROM <br /> PREPARATION AND STRUCTURAL REDESIGN. FULL HEIGHT GROUTED MASONRY WALL FROST DAMAGE DURING CONSTRUCTION. <br /> CORES.ADD#2 HORIZONTAL TIE BARS 0 <br /> SOIL EXCAVATION 8'O.C.(EACH COURSE). PRECAST PLANK: <br /> INITIAL EXCAVATION: REMOVE 5011.5 DOWN SLABS-ON-GRADE: DESIGN LOADS: DE51GN PLANK FOR ALL CODE <br /> TO SUB-GRADE BEARING ELEVATIONS. REQUIRED LOADS, PLUS •REQUIRED TOPPING, <br /> ADDITIONAL EXCAVATION: IF UNSUITABLE PERFORMANCE: CONTRACTOR SHALL MAKE PLUS ANY ADDITIONAL LOADS SHOWN ON <br /> SOILS ARE ENCOUNTERED AT THE INITIAL SUB- ADEQUATE PROVISION TO MINIMIZE SHRINKAGE DRAWINGS. CONNECT PLANKS FOR MINIMUM <br /> GRADE ELEVATION,CONTRACTOR SHALL CARRY OR SETTLEMENT CRACKS. THE FOLLOWING ARE 3009 PER F00T HORIZONTL SHEAR. <br /> RECOMMENDED <br /> EXCAVATION DEEPER UNTIL SATISFACTORY • PLANK TOPPING: SEE ARCHITECTURAL FOR <br /> SOILS ARE FOUND. ALTERNATELY. CONTRACTOR CONCRETE STRENGTH:MIN.F'c=4000 PSI. MINIMUM REQUIRED SLOPE AND DIRECTION OF <br /> MAY PROCEED A5 DIRECTED BY 501L ENGINEER. MINIMUM THICKNESS: 4 INCHES. UNLESS SLOPE.MINIMUM TOPPING THICKNE55=2' <br /> NOTED GREATER ON DRAWINGS. PLANK BEARING: PRECAST MFR. SHALL BE <br /> COMPACTED FILL SLUMP:2'TO 3'PER ASTM C143-90A. RESPONSIBLE FOR DESIGN AND DETAILING OF <br /> ALL PLANK BEARING CONDITIONS.PLANK SHALL <br /> BELOW FOOTINGS: SHALL BE SATISFACTORY REINFORCEMENT:6 X 6/M.4 X MA WELDED BEAR MINIMUM 5 INCHES ON CONCRETE WALLS <br /> SOILS COMPACTED IN 8' TO 12' LIFTS TO WIRE FABRIC. OR STEEL BEAM HEADERS AT ALL LOCATIONS. <br /> MINIMUM 98% OF MAXIMUM DRY PEN51TY PER PLANK CONNECTIONS: PRECAST MFR.SHALL <br /> ASTM 0698(STANDARD PROCTOR). WALL FOOTINGS: BE RESPONSIBLE FOR DESIGN OF ALL PLANK <br /> UNDER SLABS-ON-GRADE: SHALL BE CONNECTION DETAILS. CONNECTIONS SHALL BE <br /> SATISFACTORY 501LO COMPACTED SIMILAR TO CONCRETE STRENGTH:MIN.F2=3000 PSI. FOR MINIMUM 6009 PER FOOT IN THE DIRECTION <br /> THAT BELOW FOOTINGS. EXCEPT AL50 PROVIDE STEPPED FOOTINGS:STEP AT MAXIMUM RATIO PERPENDICULAR TO WALLMEADER AND 400# <br /> A 6'BED OF WELL-GRADED SAND(SW)IMMEDI- OF 6 VERTICAL TO 12 HORIZONTAL STEP AS PER FOOT PARALLEL TO WALLJHEADER. <br /> ATELY BELOW SLAB BEARING. NEEDED TO MAINTAIN FOOTING BEARING BELOW DEFLECTION: MAXIMUM ALLOWABLE DEFLEC- <br /> AGAINST FOUNDATION WALLS: BACKFILL MINIMUM REQUIRED FROST DEPTH. TION SHALL BE AS FOLLOWS: <br /> SHALL BE SATISFACTORYSOILS FREE OF ROCK GENERAL: CENTER FOOTING ON WALL. LAP • FLOORS:TOTAL LOAD:L/360.1/2'MAXIMUM. <br /> OR GRAVEL LARGER THAN 2" DIAMETER COM- REINFORCING MINIMUM 16'AT ALL SPLICES. LIVE LOAD: U600 TO MINIMIZE CRACKING <br /> PACTED IN 8'TO 12'LIFTS TO MINIMUM 95%OF WHEREVER THERE 15 EXPOSED CONCRETE <br /> MAXIMUM DRY DENSITY PER ASTM 0698 WF20 TYPICAL FOOTING: 20" WIDE BY 10' TOPPING. <br /> (STANDARD PROCTOR). DEEP WITH (2) 94 BOTTOM BARS <br /> AGAINST RETAINING WALLS: BACKFILL SHALL CONTINUOUS. BEARING PADS: RANDOM ORIENTED FIBER <br /> BE GOOD QUALITY SAND(5W)FOR MINIMUM 18' WF16 FOOTING:16'WIDE BY 10' DEEP WITH REINFORCED:F'C=3000 PSI. <br /> TO 24" AWAY FROM WALL, AND FOR FULL (2)94 BOTTOM BARS CONTINUOUS. MEMBRANE: AT GARAGE AND OTHER LOCA- <br /> HEIGHT OF WALL. COMPACT IN 8' TO 12' LIFTS TIONS WHERE PLANK MAY BE EXPOSED TO COR- <br /> TO MINIMUM OF 95%OF MAXIMUM DRY DENSITY SQUARE FOOTINGSR05IVE MATERIALS. PROVIDE IMPERMEABLE <br /> : <br /> PER ASTM P698(STANDARD PROCTOR). MEMBRANE BETWEEN PLANK AND TOPPING PER <br /> CONCRETE STRENGTH:MIN.F =3000 P51. <br /> PRE-CAST MANUFACTURER"5 REQUIREMENTS. <br /> 'c <br />
The URL can be used to link to this page
Your browser does not support the video tag.