My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
02-21-2017 Planning Commission Packet
Orono
>
Planning Commission
>
2017
>
02-21-2017 Planning Commission Packet
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/5/2018 10:18:23 AM
Creation date
2/5/2018 10:16:18 AM
Metadata
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
325
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
.Orono,MN Code of Ordinances Page 9 of 10 .Orono,MN Code of Ordinances Page 10 of 10 <br /> Principal buildings and structures and any building or structure accessory a. it is not the intent of the city to restrict design freedom unduly when reviewing <br /> thereto located in the B-6 zone shall be buffered from residential lots project architecture in connection with a site and building plan.However,it is in the <br /> located in any R distrIct. best interest of the city to promote high standards of architectural design and <br /> Off-street parking facilities containing six or more spaces shall be buffered compatibility with surrounding structures and neighborhoods.Architectural plans <br /> from streets located within 50 feet.Parking facilities shall be buffered with shall be prepared by an architect or other qualified persons acceptable to the city <br /> landscape zones. and shall show the following for all structures in the B-6 district: <br /> External loading and service areas must be completely screened from the 1. Elevations of all sides of the building. <br /> ground-level view from contiguous residential or commercial properties and 2. Type and color of exterior building materials. <br /> adjacent streets,except at access points. 3. A typkal floor plan. <br /> iv. All trash and trash handling equipment shall be stored within the principal 4. Dimensions of all structures. <br /> structure,within an attached structure accessible from within the principal 5. The location of trash and recycling containers and of heating,ventilation and air <br /> structure,or totally screened from eye-level view from public streets and conditioning equipment. <br /> adjacent residential properties. - Unadorned prestressed concrete panels,concrete block and unfinished metal shall <br /> v. The ground-level view of all mechanical utilities shall be completely screened not be permitted as exterior materials for principal and accessory buildings.This <br /> from contiguous properties and adjacent streets,or designed to be restriction shall apply to all principal structures and to all accessory buildings.The <br /> compatible with the architectural treatment of the principal structure. city may,at its discretion,allow architecturally enhanced block or concrete panels. <br /> vi. The light from automobile headlights and other sources shall be screened Accessory buildings shall be architecturally compatible with principal structures. <br /> whenever it may be directed onto adjacent residential windows. Accessory structures for trash and trash handling equipment shall be constructed of <br /> 2. Required screening or buffering maybe achieved with fences,walls,earth the same building material as the principal structure and be readily served through <br /> berms,hedges,or other landscape materials.All walls and fences shall be swinging doors. <br /> architecturally harmonious with the principal building.Earth berms shall not .+ All rooftop or ground-mounted mechanical equipment and exterior trash and <br /> exceed a slope of 3:1.The screen shall be designed to employ materials which recycling storage areas shall be fully enclosed or screened so as to not be visible with <br /> provide an effective visual barrier during all seasons, materials compatible with the principal structure. <br /> 3. All required screening or buffering shall be located on the lot occupied by the e. Underground utilities shall be provided for all new and substantially renovated <br /> use,building,facility or structure to be screened.No screening or buffering shall structures(the term"substantially renovated"shall mean when the renovations <br /> be located on any public right-of-way or within eight feet of the traveled portion exceed 30 percent of the prerenovation value of the structure). <br /> of any street or highway. <br /> 4. Screening or buffering required by subsection(8)of this section shall be of a (Code 1984,5 10.45(6);Ord,No.201 2nd series,5 1,2-12-2001;Ord.No.18 3rd series,5 3,9-27- <br /> 2004;Ord.No.94 3rd series,§3,9-24-2012;Ord.No.173 3rd series,§16,5-27-2016) <br /> height needed to accomplish the goals of subsection(8)of this section. <br /> Screening methods incorporating roofs over storage,trash or mechanical <br /> Secs.78-798-78-820.-Reserved. <br /> facilities to screen from higher adjacent properties or buildings may be required. <br /> Height of plantings required under subsection(8)of this section shall be <br /> measured at the time of Installation. <br /> (9) Architectural standards. <br /> about:blank 1/24!2017 about:blank 1/24/2017 <br />
The URL can be used to link to this page
Your browser does not support the video tag.