2016-01205 - new septic mound
Orono
>
Property Files
>
Street Address
>
N
>
North Arm Drive
>
495 North Arm Drive - 06-117-23-31-0014
>
Septic
>
2016-01205 - new septic mound
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 5:26:18 PM
Creation date
2/1/2018 2:50:21 PM
Metadata
Fields
Template:
x Address Old
House Number
495
Street Name
North Arm
Street Type
Drive
Address
495 North Arm Dr
Document Type
Septic
PIN
0611723310014
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
24
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
INSPECTOR CHECKLIST - mound <br /> 945 North Arm Unve i <br /> � WELL setbacka: 20'to pressure tested sewer tlne (5 psi for 15 minj <br /> 5d`to everythtng 140'to dispersak area with shatlaw weU <br /> i <br /> PROAER"PY LIAfES setback: 10'to everything � <br /> Road setback: ptatt$d: 1Q'prop 11ne. Metes 8�bounds:out of road easement,or outer ditch. k <br /> LAKE/HLUFF secback: 20'for bEuff. Lakes:GD_,_, RD„_, NE_. Ptotected wettand_. � <br /> Building s�tbacks: 10'for everything, 20'for dlspersal area. � <br /> WATBR LFNE under pressure se 10'to bed,tank�sewer tine. (etse sewer tine> 12"below) <br /> i <br /> ❑ � <br /> Sewer[ine fc haffle connectia� (no 9�s� 3'between 45's, slape min 1"in 8', max 2"fn 8') ; <br /> (no depth req's, ctean aut every 100', Sch 40 pi�y � <br /> � Septic tank and risers (water tight� inaulated, proper depth,existing verifled by pumping) ; <br /> mfg 2250 gattons none � <br /> Riser over outtet, riser over fntet or center,and b"+ inspectfon pipe over any remaining baffles. i <br /> No effluer�t Nlter�atarm <br /> Dose tank risers and piping (water tigt►t, insulated, proper depth,drainback) � <br /> mf� 1300 gallons ' <br /> � <br /> Q dose pump 36 gpm 14 head VERiFY PUMP CURVE 5.3 min oN 9 hr OFF � <br /> � float setting drop 7.5 inches at 25.5 gpi "DESIGNED" 4.8 inches approx ftaat tether tength <br /> 192.0 gal dase divided by gpi "tNSTALLED`m inches ftoat drop(field cofrected <br /> LABEL pump rec�uirements and drawdown on riser w panel j <br /> Cam lock reachable from grade- 34"max. J-hook weep hote. Suppty tfne access (no hard 90's) ; <br /> 2.d lnch supply p1pe:Sch40, sloped 1/8"+, supported by�4"sch4f}steeve or compacted, and buried 6"+. � <br /> splke box/control panel/etectrkat connections � <br /> ilow measuremer�t:CT, ETM, time dosed, home water rneter � <br /> mound absorption area rough up + <br /> mound rock dtmertsfons 1 Q.0 X 63.0 � <br /> Sand tift depth t8 tnches. (Jar test: 2"sand teaves< 1/S"sitt after 30 min) i <br /> � Absorptiott Sand beyond rock 0.0 upstope i 7.0 downsiope � <br /> I <br /> � Bem►ed topsoit beyond rockbed 12 upstope 16 sideslope 21 downstope � <br /> cover depth of 12•18"+ VERIFY <br /> 3 taterais (t-2`Erom edge of rock) <br /> 2.00 inch pipe stae (Sch40 pipe tt fittirtgs) <br /> 3.0 ft laterat spacing <br /> 8 7/32 inch pertorations <br /> 3.0 ft perforat�n spacinq <br /> Air inle#at end of taterats, and at top feed manifotd if necessary. VERIFY <br /> clean outs (no hard 90's) <br /> 4"inspection pipe to bottom of rock, anchored YERIFY <br /> Abandon exfsting system- if necessary �Re-use existing tank certtficatton <br /> monitoring ptan and type <br /> wetl aban�nment form - ff necessary <br /> I <br />