Laserfiche WebLink
Aggregate Make-Up Air Alternative and Ventilation Documentation <br /> R0 N00 C`5 P I (Can be Used as a Supplement to Permit Application) <br /> Bldg Address: 14753 NORTHSHORE DRIVE I Date: 5/15/03 <br /> City: I Orono I Zip Code: <br /> Completed By: PAUL VOGSTROM Co. Name:VOGUE HOMES,INC. <br /> Path 1, Aggregate Alternative Exhaust Devices CFM <br /> Space Heater: Sealed Combustion Clothes Dryer 150 <br /> Water Heater: Direct Vented Kitchen Exhaust 0 <br /> Gas Hearth: Sealed Combustion 1st FI Bathroom 50 <br /> Solid Fuel Hearth: None 2nd FI Bathroom 50 <br /> CO Alarm: Not Required Master Bathroom 50 <br /> Laundry Room 50 <br /> Make-Up Air Requirements Central Vacuum None <br /> Exhaust Devices Dryer Kitchen Largest Other Total <br /> Exhaust Capacity 150 0 50 200 <br /> Distribution CFM <br /> Passive Infiltration 175 <br /> Passive Opening(s) Rigid Flex Direct <br /> 25 3 4 2 <br /> Powered Make-Up <br /> 0 <br /> Ventilation Minimum Required <br /> Sq.Ft. Bedrms Total Ventilation People Ventilation *Supplemental Ventilation <br /> 2955 4 148 75 73 <br /> People installed ventilation in excess of the required minimum people is deducted from the required minimum <br /> supplemental. This is based on the Energy Code definition of Supplemental=Total minus People. <br /> People Supplemental <br /> HRV or ERV 1 180 cfm. HRV or ERV 1 0 cfm. <br /> People: 180 cfm. Supplemental : 0 cfm. Total: 180 cfm. <br />