Laserfiche WebLink
Page 2 of 3 Research Report No.99-8.1 <br /> Items requiring verification • Building construction type. <br /> The following items are related to the use ofthe report subject,but • The on center spacing of the supporting construction. <br /> not within the scope of this evaluation.However,these items are <br /> related to the determination of code compliance: • The design live load imposed on Nexwood Decking. <br /> ✓ Construction documents indicating compliance with this • Type and location of fasteners to secure Nexwood Decking <br /> report. to the supporting construction. <br /> ✓ Determination of the requirements for slip resistance for the • Design calculations and details verifying the ability of the <br /> specific application. construction supporting Nexwood Decking,including but <br /> not limited to the posts,beams,j oists and associated connec- <br /> tions to carry all superimposed loads placed upon them as <br /> Information submitted required by Chapter 16 of the BOCA National Building <br /> Code/1999. These documents shall be prepared by an <br /> ■ Intertek Testing Services Report, No. 284-4927-1, dated individual qualified in the application of the structural <br /> January 28, 1999, containing results of testing to determine design principles involved.The individual preparing such <br /> flexural stress, linear thermal expansion, and coefficient of documents shall possess the registration or license in <br /> friction in accordance with ASTM D790, D696 and D2394, accordance with the professional registration laws of the <br /> respectively. state in which the project is constructed. <br /> ■ Intertek Testing Services Report, No. 284-4872-1, dated <br /> February 8,1999,revised September 9,1999,containing results product Identification <br /> of testing to determine impact resistance,rate of burning and <br /> screw withdrawal in accordance with ASTM D256,D635 and Nexwood Decking,orthe packaging,manufactured in accordance <br /> D 1037,respectively.Full-scale load tests were also conducted with this research report shall bear the following identification: <br /> to determine design loads. ■ "See BOCA Evaluation Services,Inc. Research Report No. <br /> ■ Intertek Testing Services Report,No.193-7122,dated February 99-8." <br /> 4, 1999, revised September 9, 1999, containing results of <br /> testing to determine surface burning,in accordance with ASTM • Additionally, each piece of Nexwood Decking shall have a <br /> E84.The results indicate that Nexwood Decking has a flame permanent label containing the mark of the third-party inspec- <br /> spread index of 65 and a smoke-developed index of 340. tion agency,Intertek Testing Services. <br /> ■ Report No.R9905-1,by T.C.Chan,P.Eng.,dated February 2, <br /> 1998, containing calculations to determine the allowable kit <br /> uniformly distributed live and uplift loads ofNexwood 2x6,2- <br /> Rib Decking.Using the load test data,the allowable loads were <br /> governed by the allowable deflection. <br /> ■ Ortech Report,No.97-J23-3397-13-2,dated March 17,1997, <br /> containing results of testing to determine the results of acceler- <br /> ated weathering in accordance with ASTM G26. <br /> ■ Intertek Testing Services Inspection Manual,dated July 1999, <br /> and CRF Technologies Group Ltd.Quality Procedure Manual, <br /> dated July 1999,signed by representatives of Intertek Testing <br /> Services and CRF Technologies Group Ltd., containing <br /> procedures for maintaining the quality assurance program for <br /> Nexwood Decking and establishing Intertek Testing Services <br /> as the third-party inspection agency. <br /> application for permit <br /> To aid in the determination of compliance with this research <br /> report,the following represents the minimum level of information <br /> to accompany the application for permit: <br /> ■ The language"See BOCA Evaluation Services,Inc.Research <br /> Report No.99-8." <br /> ■ Construction documents consistent with this report shall be <br /> provided with permit applications.The following items,at a <br /> minimum,shall be provided on the construction documents: <br /> BOCA International Evaluation Report <br />