My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2017-01665 - new structure
Orono
>
Property Files
>
Street Address
>
B
>
Boulder Drive
>
765 Boulder Drive - PID: 33-118-23-11-0134 - New PID
>
Permits/Insepctions
>
2017-01665 - new structure
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:45:09 PM
Creation date
1/29/2018 3:31:19 PM
Metadata
Fields
Template:
x Address Old
House Number
765
Street Name
Boulder
Street Type
Drive
Address
765 Boulder Drive
PIN
3311823110134
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
32
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Section E <br /> Make-up air <br /> Q Passive (determined from calculations from Table 501.3.1) <br /> Powered(determined from calculations from Table 501.3.1) <br /> Interlocked with exhaust device(determined from calculation from Table 501.3.1) <br /> Other,describe: None Needed <br /> Location of dUCt Or system ventilation make-up air: Determined from make-up air opening table <br /> Cfm Size and type(round,rectangular,flex or rigid) <br /> Directions -In order to determine the makeup air, Table 501.3.1 must be filled out(see below). For most new <br /> installations, column A will be appropriate, however, if atmospherically vented appliances or solid fuel appliances are <br /> installed, use the appropriate column. For existing dwellings,see IMC 501.3.3. Please note, if the makeup air quantity <br /> is negative, no additional makeup air will be re-quired for ventilation, if the value is positive refer to Table 501.3.2 and <br /> size the opening. Transfer the cfm, size of opening and type(round, rectangular, flex or rigid) to the last line of section D. <br /> The make-up air supply must be installed per IMC 501.3.2.3. <br /> Table 501.3.1 <br /> PROCEDURE TO DETERMINE MAKEUP AIR QUANITY FOR EXHAUST EQUIPMENT IN DWELLINGS <br /> (Additional combustion air will be required for combustion appliances,see KAIR method for calculations) <br /> One or multiple power One or multiple fan- One atmospherically vent Multiple atmospherically <br /> vent or direct vent assisted appliances and gas or oil appliance or vented gas or oil appliances <br /> appliances or no power vent or direct one solid fuel appliance or solid fuel appliances <br /> combustion appliances vent appliances <br /> Column A Column B Column C Column D <br /> 1' 0.15 0.09 0.06 0.03 <br /> a)pressure factor(cfm/sf) <br /> b)conditioned floor area(sf) 3658 <br /> (including unfinished basements) <br /> Estimated House Infiltration(cfm): 548 <br /> [lax 1b] <br /> 2.Exhaust Capacity <br /> a)continuous exhaust-only N/A <br /> ventilation system(cfm);(not <br /> applicable to balanced ventilation <br /> systems such as HRV) <br /> b)clothes dryer(cfm) 135 135 135 135 <br /> c)80%of largest exhaust rating(cfm); <br /> Kitchen hood typically(not applicable .8 X 300 = 240 <br /> if recirculating system or if powered <br /> makeup air is electrically interlocked <br /> and match to exhaust) <br /> d)80%of next largest exhaust rating <br /> (cfm); bath fan typically(not Not <br /> applicable if recirculating system or if <br /> powered makeup air is electrically Applicable <br /> interlocked and matched to exhaust) <br /> Total Exhaust Capacity(cfm); 375 <br /> [2a+2b+2c+2d] <br /> 3.Makeup Air Quantity(cfm) 375 <br /> a)total exhaust capacity(from above) <br /> b)estimated house infiltration(from 548 <br /> above) <br /> Makeup Air Quantity(cfm): <br /> [3a—3b](if value is negative,no -173 <br /> makeup air is needed) <br /> 4.For makeup Air Opening Sizing, <br /> refer to Table 501.4.2 None needed <br /> A. Use this column if there are other than fan-assisted or atmospherically vented gas or oil appliance or if there are no combustion appliances.(Power <br /> vent and direct vent appliances may be used.) <br /> B. Use this column if there is one fan-assisted appliance per venting system.(Appliances other than atmospherically vented appliances may be included.) <br /> C. Use this column if there is one atmospherically vented(other than fan-assisted)gas or oil appliance per venting system or one solid fuel appliance. <br /> D. Use this column if there are multiple atmospherically vented gas or oil appliances using a common vent or if there are atmospherically vented gas or <br /> oil appliances and solid fuel appliances. <br /> 3 <br />
The URL can be used to link to this page
Your browser does not support the video tag.