My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2017-01665 - new structure
Orono
>
Property Files
>
Street Address
>
B
>
Boulder Drive
>
765 Boulder Drive - PID: 33-118-23-11-0134 - New PID
>
Permits/Insepctions
>
2017-01665 - new structure
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:45:09 PM
Creation date
1/29/2018 3:31:19 PM
Metadata
Fields
Template:
x Address Old
House Number
765
Street Name
Boulder
Street Type
Drive
Address
765 Boulder Drive
PIN
3311823110134
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
32
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Ventilation, Makeup and Combustion Air <br /> Calculations Submittal Form For New <br /> Dwellings <br /> Site address 765 Boulder Dr., Orono, MN Date 12/21/17 <br /> Contractor Wooddale Builders Completed By Riccar Htg. and Air <br /> Section A <br /> Ventilation Quantity <br /> (Determine quantity by using Table N1104.2 or Equation 11-1) <br /> Square feet(Conditioned area including basement— 3658 Total required ventilation 133 <br /> finished or unfinished) _ <br /> Number of bedrooms 3 Continuous ventilation 67 <br /> Directions -Determine the total and continuous ventilation rate by either using Table N1104.2 or equation 11-1. <br /> The table and equation are below. <br /> Table N1104.2 <br /> Total and Continuous Ventilation Rates(in cfm) <br /> Number of Bedrooms <br /> 1 2 3 4 5 6 <br /> Conditioned space Total/ Total/ Total/ Total/ Total/ Total/ <br /> (in sq. ft.) continuous continuous continuous continuous continuous continuous <br /> 1000-1500 60/40 75/40 90/45 105/53 120/60 135!68 <br /> 1501-2000 70/40 85/43 100!50 115/58 130/65 145/73 <br /> 2001-2500 80/40 95/48 110/55 125/63 140/70 155/78 <br /> 2501-3000 90/45 105/53 120/60 135/68 150/75 165/83 <br /> 3001-3500 100/50 115/58 130/65 145/73 160/80 175/88 <br /> 3501-4000 110/55 125/63 140/70 155/78 170/85 185/93 <br /> 4001-4500 120/60 135/68 150/75 165/83 180/90 195/98 <br /> 4501-5000 130/65 145/73 160/80 175/88 190/95 205/103 <br /> 5001-5500 140/70 155/78 170/85 185/93 200/100 215!108 <br /> 5501-6000 150/75 165/83 180/90 195/98 210/105 225/113 <br /> Equation 11-1 <br /> (0.02 x square feet of conditioned space) +[15 x(number of bedrooms+ 1)]=Total ventilation rate(cfm) <br /> Total ventilation—The mechanical ventilation system shall provide sufficient outdoor air to equal the total ventilation rate <br /> average,for each one-hour period according to the above table or equation. For heat recovery ventilators (HRV) and <br /> energy recovery ventila-tors (ERV) the average hourly ventilation capacity must be determined in consideration of any <br /> reduction of exhaust or out outdoor air intake, or both, for defrost or other equipment cycling. <br /> Continuous ventilation -A minimum of 50 percent of the total ventilation rate, but not less than 40 cfm, shall be provided, <br /> on a con-tinuous rate average for each one-hour period. The portion of the mechanical ventilation system intended to be <br /> continuous may have automatic cycling controls providing the average flow rate for each hour is met. <br /> 1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.