Laserfiche WebLink
Aggregate Make-Up Air Alternative and Ventilation Documentation <br /> (Can be Used as a Supplement to Permit Application) <br /> Zip Code: <br /> City Orono ' 55323 <br /> BldgAddress: 4515 North Shore Drive ate: 7_/15/2004 <br /> Completed By: Kevin Kamerud Co. Name: Stonewood Design Build, LLC <br /> Path 1, Aggregate Alternative rExhaust Devices CFM <br /> Space Heater: Direct Vented Clothes Dryer 150 <br /> Water Heater: Direct Vented Kitchen Exhaust 300 <br /> Gas Hearth: Direct Vented Master Bathroom 80 <br /> Solid Fuel Hearth: None Bsmt Bathroom 80 <br /> CO Alarm: Not Required Bsmt Bathroom 80 <br /> Make-Up Air Requirements Central Vacuum None <br /> Exhaust Devices Dryer Kitchen Largest *Excess Total <br /> Other Vent. <br /> Exhaust Capacity 150 0 0 313 463 <br /> *Passive opening cfms required for exhaust supplemental ventilation in excess of 0.05 X total Sq. Ft. <br /> Distribution CFM <br /> Passive Infiltration 175 <br /> Passive Opening(s) Rigid Flex Direct <br /> 288 9 10 8 <br /> Powered Make-Up <br /> 0 <br /> Ventilation Minimum Required <br /> Sq. Ft. Bedrms Total Ventilation People Ventilation Supplemental Ventilation <br /> 4532 3 227 60 167 <br /> People Supplemental <br /> HRV or ERV 1 144 cfm. HRV or ERV 1 88 cfm. <br /> Kitchen Exhaust 0 cfm. Kitchen Exhaust 300 cfm. <br /> Master Bathroom 0 cfm. Master Bathroom 80 cfm. <br /> Bsmt Bathroom 0 cfm. Bsmt Bathroom 80 cfm. <br /> Bsmt Bathroom 0 cfm. Bsmt Bathroom 80 cfm. <br /> Applicant(print name) Signature Date 7 Phone number <br />