My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SEptic Design
Orono
>
Property Files
>
Street Address
>
L
>
Lakeview Parkway
>
765 Lakeview Parkway - 06-117-23-34-0010
>
Correspondence
>
SEptic Design
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 5:27:33 PM
Creation date
1/24/2018 12:38:19 PM
Metadata
Fields
Template:
x Address Old
House Number
765
Street Name
Lakeview
Street Type
Parkway
Address
765 Lakeview Pkwy
Document Type
Correspondence
PIN
0611723340010
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
32
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
INSPECTOR CHECKLIST - mound <br /> /65 Lakeview Parkway <br /> 1'11:1.1. setbacks: 20'to pressure tested sewer line (5 psi for 15 min) <br /> 50'to everything 100'to dispersal area with shallow well <br /> PROPER I Y LINES setback: 10'to everything <br /> Road setback: platted: 10' prop tine. Metes& bounds: out of road easement, or outer ditch. <br /> 1..1K1. Bid'FP setback: 20'for bluff. Lakes: GD_, RD_, NE_. Protected wetland_ <br /> 13uilding setbacks: 10'for everything, 20'for dispersal area. <br /> \A I ER LINT:under pressure s.10'to bed,tank & sewer line. (else sewer tine > 12"below) <br /> nSewer line & baffle connection (no 90's, 3'between 45's, slope min 1" in 8', max 2" in 8') <br /> (no depth req's, clean out every 100', Sch 40 pipe) <br /> nSeptic tank and risers (water tight, insulated, proper depth, existing verified by pumping) <br /> mfg 2250 gallons none <br /> Riser over outlet, riser over inlet or center, and 6"+ inspection pipe over any remaining baffles. <br /> _ No effluent filter Et alarm <br /> Dose tank risers and piping (water tight, insulated, proper depth, drainback) <br /> mfg 1300 gallons <br /> dose pump 36 gpm 27 head VERIFY PUMP CURVE 5.7 min ON 9 hr OFF <br /> n float setting drop 8.0 inches at 25.5 gpi "DESIGNED" 5.0 inches approx float tether length <br /> 204.0 gal dose divided by gpi "INSTALLED" = inches float drop (field corrected <br /> LABEL pump requirements and drawdown on riser or panel <br /> Cam lock reachable from grade - 30"max. J-hook weep hole. Supply line access (no hard 90's) <br /> 2.0 inch supply pipe: Sch40, sloped 1/8"+, supported by 4"sch40 sleeve or compacted, and buried 6"+. <br /> splice box / control panel / electrical connections <br /> flow measurement: CT, ETM, time dosed, home water meter <br /> mound absorption area rough up <br /> mound rock dimensions 10.0 X 63.0 <br /> Sand lift depth 14 inches. (Jar test : 2"sand leaves < 1/8"silt after 30 min) <br /> nAbsorption Sand beyond rock 0.0 upslope 17.0 downslope <br /> Bermed topsoil beyond rockbed 9 upslope 13 sideslope 27 downslope <br /> cover depth of 12-18"+ VERIFY <br /> 3 laterals (1-2'from edge of rock) <br /> 2.00 inch pipe size (Sch40 pipe &fittings) <br /> 3.0 ft lateral spacing <br /> 7/32 inch perforations <br /> 3.0 ft perforation spacing <br /> Air inlet at end of laterals, and at top feed manifold if necessary. VERIFY <br /> _ clean outs (no hard 90's) <br /> 4"inspection pipe to bottom of rock, anchored VERIFY <br /> Abandon existing system - if necessary Re-use existing tank certification <br /> monitoring plan and type <br /> well abandonment form - if necessary <br />