Laserfiche WebLink
New Construction Energy Code Compliance Certifcate <br /> Per N1101.8 Building Certificate.A building cettificate shall be posted in a permanenUy visble location inside De[e CertlBcete Posted <br /> the bw7d'mg.�The certificate shell be completed by the builder and shall list information and values of <br /> componeots listed'm Table N1101.8. <br /> MaWng Address of the Dweltlng or DwelHng Udt City <br /> 4415 North Shore Drive Orono <br /> Neme of Restdentlsl Contractor MN Idcense Number <br /> HERMAL ENVELOPE RADON SYSTEM <br /> Tppe:Ch�k All That Applr X Passive(No Fan) <br /> o d <br /> � Active(�th fan and monometer or <br /> F °� <br /> A ,� other system monitoring device) <br /> �s � a '� a a� <br /> � � � � � � �3 � <br /> � d o� ora �3 � '� '" �', <br /> Insulatlon Locatlon � .� z � � i� g' � � � <br /> ° �m o �° � � <br /> z w w w° w° � r� r� Other Please Describe Here <br /> Below Entire Slab <br /> Foundat[on Wall Type in IocaUon:Interior extedor or iMegral <br /> Perimeter of Slab on Grade <br /> Rim Joist(Foundatton) Type in Ixatlon:Interior exterior or integral <br /> Rim Joist{1°�FIoOr+) 7ype in locatlon:hrterior e�darior or integral <br /> w8u <br /> c�,�t <br /> c�g,�a�tea <br /> Bay Windows or candlevered areas <br /> Bonus room over garage <br /> Describe otherinsalated areas <br /> �ndows&Doors eating or Cooling Duefs Outside Condifioned Spaces <br /> Average U-Factor(excludes skylights and one door)U: Not applicable,all ducts located in conditioned space <br /> Solar Heat Gain Coefficient(SHGC): R-value <br /> ECHANICAL SYSTEMS Make-up Air Select a Type <br /> A pliances Heating System Dom�stic Water Heater Cooling System X Not required per mech.code <br /> Fuel Type NG Passive <br /> Manutacturer CARRIER CARRIER Powered <br /> Interlocked with exhaust device. <br /> Model 58MCB 24ABB3 Describe: <br /> Input in 140000 CapecitY in Output in 5.5 Other,describe: <br /> Rating or Size BT[7S: Gallons: Tons: <br /> Heat Loss: 139920 Heat Gain: 5672 Location of duct or system: <br /> Stractare's Calcalated <br /> AFUE or Q,92 SEER: 13 <br /> HSPF% <br /> Caiculated 64955 <br /> Efficlenc coo' laad: Cfm's <br /> "mund duct OR <br /> Mechanical VerMilation Sysfem "metal duct <br /> Describe any addidonal or combined heating or cooling systems if installed:(e.g.two furnaces or air Combustion Air Select a Type <br /> ource heat pump with gas back-up furnace):Two forced air furnace!a/c systems each with HRV and humidiHer. Not required pa mech.code <br /> Select Type Passive <br /> Heat Recover Ventilator(HR� Capacity in cfms: Low: 117/64 High: 189/150 Other,describe: <br /> Energy R�over Ventilator(ER�Capacity in cfms: Low: High: Locadon of duct or system: <br /> Continuous exhausting fan(s)rated capacity in cfms: <br /> I.ocation of fan(s),describe: Cfm's <br /> Capacity continuous ventilation rate in cfms: 1 6 "mund duct OR <br /> Total ventilation(intermittent+continuous)rate in cfms: �i "metal duct <br /> Created by BAM version 052009 <br />