Laserfiche WebLink
Wall framing by others <br /> Sill plate by others w/1/2" <br /> diameter anchor bolts w/7" <br /> minimum embed&standard <br /> washers @ 72"o.c.max or <br /> Optional slab ledge,maximum equivalent metal strap anchors <br /> stem height is 12"w/width to (Anchor bolt clearance between <br /> edge of both wall and sill plate is <br /> match sill plate <br /> to be 2") <br /> Grade to be at least 6"below top <br /> of wall <br /> (1)#4 continuous horizontal bar <br /> w/in 18"of top of wall <br /> { 6"minimum thick cast-in-place <br /> concrete wall <br /> #4 x 2'-0"long dowels @ 72"o.c. <br /> max w/5"minimum embed <br /> Unreinforced concrete strip <br /> footing per Code by others, <br /> provide frost protection per Code <br /> as required <br /> WALKOUT/ SLAB-ON-GRADE FROST WALL DETAIL <br /> Note: Maximum unbalanced fill height is 36"for 8"thick wall&48"for 10"wall <br /> Oswell Engineering and Consulting,LLC. 1901 E Hennepin Ave,#201 . • <br /> Project Name: 2017 Standardized Concrete Foundation Drawings Minneapolis,MN 55413 <br /> Description: Frost Wall Detail(NOT TO SCALE) Phone:612-720-4639 <br /> Mrs, <br /> Project# 16.100 Fax:612-886-2966 =: 1 <br /> Client Name: Abfalter Brothers Concrete LLC www.oswelleo.com <br /> Client Address: 15546 Cleveland Street,Elk River,MN 55330 Page S4 of S6 ;r ra . <br /> 1/1/2017 <br />